Symmetrical Loss of Excitation Fault Diagnosis in an Asynchronized High-Voltage Generator
As a new type of generator, an asynchronized high-voltage generator has the characteristics of an asynchronous generator and high voltage generator. The effect of the loss of an excitation fault for an asynchronized high-voltage generator and its fault ...
Yanling Lv +4 more
doaj +1 more source
This paper introduces a novel approach for detecting inter-turn short-circuit faults in rotor windings using wavelet transformation and empirical mode decomposition.
Jianfeng Sun +6 more
core +1 more source
Early slight inter-turn short circuit fault diagnosis of axial flux stator coreless permanent magnet motor based on phase difference [PDF]
Aiming at the problem of early inter-turn short circuit fault of axial flux stator coreless motor, a method for early inter-turn short circuit fault diagnosis and positioning of axial flux stator coreless motor based on the phase difference of zero ...
Xiaoguang WANG +4 more
doaj +1 more source
The transient characteristics of wind farms in groups are quite different; in addition, there is a strong coupling between the wind farms and the grid, and these factors make the fault analysis of the grid with wind farm groups complicated.
Weichen Qian, Jun Yin, Xiaobo Huang
core +1 more source
Detection and Diagnosis of Motor Stator Faults using Electric Signals from Variable Speed Drives [PDF]
Motor current signature analysis has been investigated widely for diagnosing faults of induction motors. However, most of these studies are based on open loop drives.
Shaeboub, Abdulkarim +9 more
core +1 more source
The Cable Fault Diagnosis for XLPE Cable Based on 1DCNNs-BiLSTM Network
Diagnosing the fault type accurately from a variety of faults is very essential to ensure a stable electricity supply when a short-circuit fault occurs.
Qianyu Wang +4 more
doaj +1 more source
Due to the pseudo-bipolar structure of the flexible DC distribution network, the short-circuit current caused by a pole-to-ground fault is weak. The fault characteristics, particularly the steady-state fault characteristics, are not prominent. Therefore,
Hao Qi +6 more
doaj +1 more source
DC short-circuit fault simulation waveform.
DC short-circuit fault simulation waveform.
Qiaozhen Zhang (14241811) +3 more
core +1 more source
Characteristics of Short-Circuit Current in Distribution Network with Doubly-Fed Wind Power System
The doubly-fed induction generator (DFIG) is connected to the distribution network as a distributed power source, which turns a radial single power supply system into a dual power supply system and changes the topology of the distribution network. When a
XI Xinze, XING Chao, QIN Risheng, HE Tingyi, HE Peng, MENG Xian, CHENG Chunhui
doaj +1 more source
An Analytical Short-Circuit Current Calculation Method for Full-Power Wind Turbines under Complete Fault Ride-Through Processes [PDF]
Accurate calculation of short-circuit current throughout the fault ride-through process of wind turbines is a critical prerequisite for the analysis and control of modern power systems.
YUAN Shuai, XIAO Jiaan, TAO Jun, CUI Haohan, CHAO Pupu, LI Weixing, A Minfu, WANG Liqiang, ZHONG Ming
doaj +1 more source