Results 21 to 30 of about 6,553 (260)
Inter-turn short circuit in the excitation windings of synchronous condensers is a common fault that directly impacts their normal operation. However, current fault analysis and diagnosis of synchronous condensers primarily rely on voltage-balanced ...
Junqing Li +5 more
doaj +1 more source
Fault detection method for VSC-HVDC System with new energy sources considering fault current limiter
Voltage source converter based high voltage direct current transmission (VSC-HVDC) is widely adopted in the power system with new energy sources, but with the problem of fast rise of fault current.
Jiaxin Yuan +7 more
doaj +1 more source
A Review of Short-Circuit Fault Analysis and Novel Fault Detection Methods
This paper proposes a comprehensive review of short circuit fault analysis. It presents the different definitions and classifications of faults. It then discusses both symmetrical and unsymmetrical faults in detail and provides the equations used to solve for the fault current during each of these faults.
Moayad Osman, Ibrahim O. Habiballah
openaire +2 more sources
Timely and accurate fault diagnosis for a lithium-ion battery pack is critical to ensure its safety. However, the early fault of a battery pack is difficult to detect because of its unobvious fault effect and nonlinear time-varying characteristics.
Tian-E Fan +4 more
doaj +1 more source
The analysis and calculation of the short-circuit fault current in the DC grid is of great significance to the design and configuration of the converter station and DC circuit breaker parameters.
Haipeng Jia +5 more
doaj +1 more source
A magnetic isolation IGBT driver architecture with short circuit protection
A magnetic isolation IGBT drive architecture with short circuit protection is designed in this paper. The architecture adopts transformer isolation, integrates desaturation detection circuit, Miller clamp circuit and soft turn-off.
Liu Jiajun +4 more
doaj +1 more source
Electromagnetic-force calculation and fault diagnosis of shell transformer under inter-turn short circuit [PDF]
Aiming at the electromagnetic distribution law, winding mechanical response characteristics, and degree diagnosis of inter-turn short circuit fault locations of shell-type transformers under inter-turn short circuits, the research idea of “simulation ...
Duanjiao Li +5 more
doaj +1 more source
Diversity and complexity in neural organoids
Neural organoid research aims to expand genetic diversity on one side and increase tissue complexity on the other. Chimeroids integrate multiple donor genomes within single organoids. Self‐organising multi‐identity organoids, exogenous cell seeding, or enforced assembly of region‐specific organoids contribute to tissue complexity.
Ilaria Chiaradia, Madeline A. Lancaster
wiley +1 more source
Intratumour heterogeneity complicates precision management of advanced endometrial cancer. Circulating tumor DNA (ctDNA) offers a minimally invasive strategy to capture tumor evolution and therapeutic resistance. Here, we compare tumor‐agnostic NGS with tumor‐informed ddPCR, outlining their relative sensitivity, concordance, and clinical implications ...
Carlos Casas‐Arozamena +15 more
wiley +1 more source
The flexible DC transmission system needs a DC circuit breaker to remove and isolate the bipolar short-circuit fault to prevent the excessive short-circuit current from damaging the DC transmission system.
Can Ding +3 more
doaj +1 more source

