Results 21 to 30 of about 31,150 (250)
Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach [PDF]
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter.
S. Mohammadi +2 more
doaj +1 more source
Design strategy for the combined system of shunt passive and series active filters [PDF]
A design strategy for the combined power filter for a three-phase twelve-pulse thyristor rectifier is proposed. The shunt passive filter, which can minimize the output voltage of the series active filter, is designed and tested in a prototype model.
Akagi, Hirofumi, Fujita, Hideki
core +1 more source
Shunt Active Filter Controlled by Fuzzy Logic
Harmonics contamination is a serious and a harmful problem in electric power systems. Active power filtering constitutes one of the most effective proposed solutions.
Hocine Benalla, Hind Djeghloud
doaj +1 more source
Current-source shunt active power filter with periodic-sampling modulation technique [PDF]
In this paper are presented experimental and simulation results of a developed Current-Source Three-Phase Shunt Active Power Filter compensating the currents of a non-linear load. The Shunt Active Power Filter controller, described in detail
Afonso, João L. +5 more
core +1 more source
Shunt active power filtering for smart appliances [PDF]
Due to the increasing trend towards energy saving white goods appliances and the commercial viability of power electronic components, there has been an expansion in the use of solid state electronics and variable frequency drive motors in these applications.
L. Al-Musawi +2 more
openaire +1 more source
Aiming at the heat dissipation design problem of shunt active power filter, this paper proposes a computational fluid dynamics (CFD) simulation method of module flow–heat transfer coupling under forced air cooling.
Dongdong Chen +4 more
doaj +1 more source
Increased THD (Total Harmonics Distortion) in the utility, caused by the increasing operation of non-linear loads. High THD current (THDi) will affect the increase of power losses in the power system. In this study, THD analysis of the simulation results
I Made Suartika +2 more
doaj +1 more source
PFC Topologies for AC to DC Converters in DC Micro-Grid [PDF]
With increasing dominance of renewable energy resources and DC household appliances, the novelty of DC micro grid is attracting significant attention. The key interface between the main supply grid and DC micro grid is AC to DC converter.
Ashraf, Muhammad +3 more
core +1 more source
Shunt Active Filter in Damping Harmonics Propagation
This paper deals with a hybrid shunt active power filter applied on 500 kV HVDC, after a description of the causes and effects harmonic pollution which may damage equipments and interrupt electric power customers service; in this paper we present the ...
BERBAOUI, B. +3 more
doaj +1 more source
A hybrid fuzzy sliding-mode control for a three-phase shunt active power filter [PDF]
This document is the Accepted Manuscript version of the following article: Mohamed Abdeldjabbar Kouadria, Tayeb Allaoui, and Mouloud Denai, ‘A hybrid fuzzy sliding-mode control for a three-phase shunt active power filter’, Energy Systems, Vol. 8 (2): 297-
B Singh +16 more
core +2 more sources