Results 41 to 50 of about 5,603 (270)
Line-Interactive UPS as Shunt Active Power Filter
This paper describes a newly proposed solution for using the line-interactive uninterruptible power supply (UPS) system as a shunt active power filter. An overview of active power filters topologies and control strategies for active power filters are presented. The proposed solution is compared to similar solutions.
Šunde, Viktor +2 more
openaire +2 more sources
Control Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review [PDF]
Current harmonics is one of the most significant power quality issues which has attracted tremendous research interest. Shunt active power filter (SAPF) is the best solution to minimize harmonic contamination, but its effectiveness is strictly dependent ...
Mohd Amran Mohd Radzi +7 more
core +1 more source
This paper presents an algorithm for finding the optimal control for a current controller that operates as a part of a control system of a shunt active power filter.
Krzysztof Kołek, Andrzej Firlit
doaj +1 more source
The Energy Processing by Power Electronics and its Impact on Power Quality [PDF]
This paper discusses the electrical architectures adopted in wind turbines and its impact on the harmonic flux at the connected electric network. The integration of wind electric generators with the power grid needs energy processing by power electronics.
J.E. Rocha +3 more
core +1 more source
Power Quality Improvement in Mosul City Using Shunt Active Power Filter
One of the most important issues in Mosul is power quality. A power quality issue caused by current harmonic pollution caused by a wide range of nonlinear loads in the electrical power system. The shunt active power filter based on instantaneous active
Faisal Falah Aiwa +2 more
doaj +1 more source
This work contributes to both Romania’s and the European Union’s energy policies by highlighting the research results obtained within the Dunarea de Jos University of Galati, but also through the technological transfer of this knowledge to the industry ...
Marian Gaiceanu +3 more
doaj +1 more source
Practical considerations regarding power factor for nonlinear loads [PDF]
This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted.
Zobaa, AF +3 more
core +1 more source
A fuzzy logic approach to shunt active power filter and hybrid active power filter [PDF]
This paper describes a Fuzzy Logic approach to Shunt Active power filter (SAPF) versus Hybrid Active Power Filter (HAPF) using Simulink. Here hysteresis controlled PWM method is applied to the SAPF and HAPF as a current controller and Fuzzy logic ...
Panda, Gayadhar +2 more
core
Instantaneous d frame driven Shunt active filter (SAF) alleviate harmonics and reactive power. This control algorithm evolved from elemental synchronous reference frame engenders the fundamental reference signal from the load current with a phase shift ...
Ramakrishnan Sriranjani +1 more
doaj +1 more source
In this work, low bandgap (≈1.55 eV) semitransparent perovskite solar cells (ST‐PSCs) having thin (thickness < ≈100 nm) perovskite layers and transparent conductive oxide‐based rear electrodes are fabricated using vacuum‐deposition methods. Two different ST‐PSCs demonstrated a high light utilization efficiency value of 4.2 (PCE: 9.26% and AVT: 45.3 ...
Abhyuday Paliwal +9 more
wiley +1 more source