Results 21 to 30 of about 8,202,745 (292)
Review of Fundamental Active Current Extraction Techniques for SAPF
The field of advanced digital signal processing methods is one of the fastest developing scientific and technical disciplines, and is important in the field of Shunt Active Power Filter control methods.
Jan Baros +6 more
doaj +1 more source
Sliding mode controller for four leg shunt active power filter to eliminating zero sequence current, compensating harmonics and reactive power with fixed switching frequency [PDF]
In this paper, the four leg inverter controlled by the three dimensional space vector modulation (3D SVM) is used as the shunt active power filter (SAPF) for compensating the three phase four wire electrical network, by using the four leg ...
Chebabhi Ali +3 more
doaj +1 more source
Nowadays, the integration of renewable energy sources such as solar, wind, etc. into the grid is recommended to reduce losses and meet demands. The application of power electronics devices (PED) to control non-linear, unbalanced loads leads to power ...
Koganti Srilakshmi +2 more
semanticscholar +1 more source
Quality power is a very important factor for the proper functioning of appliances and can be enhanced using shunt active power filters (SAPF). This work demonstrates the hardware implementation of synchronous reference frame (SRF) theory based SAPF. This
Ravinder Kumar +4 more
semanticscholar +1 more source
The article covers the control techniques of shunt active filters using switching devices using artificial neural network (ANN) Theory. The basic idea is to achieve perfect disturbance minimization in both steady and transient states.
Kambhampati V. B. Rao +1 more
semanticscholar +1 more source
Sliding Mode Control Based Shunt Active Power Filter [PDF]
Currentlytheshuntactivepowerfilter(APF)isaneffectivemeansofreducinginactivecomponentsofthepowerconsumedfromthenetwork.Atthesametime,theshuntAPFbeinganonlinearelementisitselfasourceofhigherharmonics,thesuppressionofwhichisimposedontheinterfacefilter ...
SkuriatinY.V. +2 more
doaj +1 more source
Introduction. Since the development of the first active power filter (APF) in 1976, many efforts have been focused on improving the performances of the APF control as the number of different nonlinear loads has continued to increase.
A. Chemidi +2 more
doaj +1 more source
Shunt active power filter (SAPF) belongs to the class of custom power devices (CPDs) and offers compensation to harmonics originated owing to customer side nonlinear loads, reactive power and unbalance in the distribution power networks functioning in ...
Mohit Bajaj +5 more
semanticscholar +1 more source
Research of double closed-loop control strategy for shunt active power filter
The paper analyzed implementation principle of double closed-loop control strategy for shunt active power filter. In view of problems that PI control cannot track AC signal without static error and repetitive control has slow dynamic response speed, the ...
REN Zi-hui +3 more
doaj +1 more source
Control Strategy of 1 kV Hybrid Active Power Filter for Mining Applications
The paper presents a shunt hybrid active power filter for 1 kV mining applications in configuration with a single-tuned passive filter. The focus is on the method of controlling the filter, with particular emphasis on the influence of network voltage ...
Dawid Buła +5 more
doaj +1 more source