Results 91 to 100 of about 1,008 (177)

Single-Phase Shunt Active Power Filter Based on a 5-Level Converter Topology

open access: yesEnergies, 2018
This paper presents a single-phase Shunt Active Power Filter (SAPF) with a multilevel converter based on an asymmetric full-bridge topology capable of producing five distinct voltage levels.
José Gabriel Oliveira Pinto   +5 more
doaj   +1 more source

Model predictive current control for a low-cost shunt active power filter [PDF]

open access: yes, 2023
Performance of a three-phase shunt active power filter (SAPF) relies on the capability of the controller to track the reference current. Therefore, designing an accurate current controller is crucial to guarantee satisfactory SAPF operation.
Abdel-Aziz, Ali A.   +2 more
core  

Multiobjective Neuro‐Fuzzy Controller Design and Selection of Filter Parameters of UPQC Using Predator Prey Firefly and Enhanced Harmony Search Optimization

open access: yesInternational Transactions on Electrical Energy Systems, Volume 2024, Issue 1, 2024.
This research introduces a unified power quality conditioner (UPQC) that integrates solar photovoltaic (PV) system and battery energy systems (SBES) to address power quality (PQ) issues. The reference signals for voltage source converters of UPQC are produced by the Levenberg–Marquardt back propagation (LMBP) trained artificial neural network control ...
Koganti Srilakshmi   +8 more
wiley   +1 more source

DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter [PDF]

open access: yes, 2017
Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its controller, DC-link capacitor voltage regulation algorithm with either proportional-integral (PI) or fuzzy logic control (FLC) technique has played a ...
Mailah, Nashiren Farzilah   +2 more
core  

Improving Power Quality of a Hybrid Grid‐Connected Photovoltaic–Wind Microgrid Using Shunt Active Power Filter and Distribution Static Synchronous Compensator

open access: yesInternational Transactions on Electrical Energy Systems, Volume 2024, Issue 1, 2024.
Unbalanced voltage and harmonics are major challenges in a microgrid. Single‐ and two‐phase loads and short circuit can make unbalanced voltage. Besides, nonlinear loads create harmonic components in the grid. Thus, compensating both of the unbalanced voltage and harmonic distortion is necessary. Otherwise, they could cause low power quality, resonance,
Ehsan Akbari   +2 more
wiley   +1 more source

A Three-Phase Grid-Connected PV System Based on SAPF for Power Quality Improvement [PDF]

open access: yes, 2017
This paper proposes a combined system of three-phase four-wire shunt active power filter (SAPF), and photovoltaic generator (PVG), to solve the power quality problems such as harmonic currents, poor power factor, and unbalanced load.
Belaidi, Rachid   +3 more
core   +4 more sources

Analysis and sliding mode control of four-wire three-leg shunt active power filter [PDF]

open access: yes, 2015
In this paper, the analysis and the sliding mode control application for a shunt active filter is presented. The active filter is based on a three-leg split-capacitor voltage source inverter which is used to compensate harmonics and unbalance in the ...
Amimeur, Hocine, Hamoudi, Farid
core   +2 more sources

Shunt Active Power Filters Based On Diode Clamped Multilevel Inverter and Hysteresis Band Current Controller [PDF]

open access: yes, 2013
This work focused to design and implementing the three phase shunt Active Power Filter (SAPF) based in instantaneous reactive power theory which we used to generate the reference current and measure the power and reactive power and power factor and using
Qashou, Akram   +2 more
core   +1 more source

Comparison of active filters topologies in medium voltage distribution power systems [PDF]

open access: yes, 2014
This paper presents the design of different topologies of active power filters to compensate reactive power and harmonics in the medium voltage level of a distribution power system. One pure active filter and two hybrid topologies, are implemented.
Arnera, Patricia Liliana   +3 more
core  

Shunt Active Power Filter untuk Meredam Harmonisa Beban Non-Linear Satu Fasa [PDF]

open access: yes, 2022
Penggunaan beban non-linear semakin umum digunakan seiring berkembangnya teknologi yang menerapkan komponen elektronika daya di dalamnya. Beban non-linear dapat menimbulkan harmonisa pada jaringan listrik dan mengakibatkan penurunan kualitas daya.
Mumtaz, Fahmi Naufala   +2 more