Results 101 to 110 of about 1,008 (177)
IET Power Electronics, Volume 17, Issue 9, Page 983-985, 24 July 2024.
Mahalingam Prabhakar +3 more
wiley +1 more source
Research on main circuit parameter coupling relationship of single-phase shunt active power filter
There is a certain coupling relationship among the main circuit parameters of a single-phase shunt active power filter(SAPF), which has a great influence on the reasonable selection of various parameter values. By analyzing the calculation methods of the
ZHANG Zi-qi +3 more
doaj
Harmonic distortion in power networks has greatly reduced power quality and this affects system stability. In order to mitigate this power quality issue, the shunt active power filter (SAPF) has been widely applied and it is proven to be the best ...
Suleiman Musa +5 more
doaj +1 more source
André Tiago Queiroz +5 more
openaire +1 more source
Fuzzy Logic Control For Three Phase Shunt Active Power Filter (Modeling And Simulation) [PDF]
The main purpose of this project is to perform studied on fuzzy logic control for a three-phase Shunt Active Power Filter (SAPF) in order to reduce total harmonic distortion and power factor correction in a distribution system supplying non-linear loads.
Aida Yanti Oredi, Aida Yanti
core
Current harmonics produced by nonlinear loads have destructive effects that affect the power quality of the power system and cause serious problems throughout the network.
Behnam Amini +2 more
doaj +1 more source
Instrumentation for Verification of Shunt Active Power Filter Algorithms. [PDF]
Baros J +6 more
europepmc +1 more source
Design a filter for harmonics caused by non-linear load and resonance coused by power factor correction capacitor [PDF]
The traditional approach to power factor correction (PFC) in industrial applications involves installation of power factor correction capacitor banks (PFCC).
Adan, Nor Faezah
core
Grid power quality enhancement by nonlinear control of voltage source inverter
Aim/Background: Maintaining power quality in grid-connected systems with renewable energy sources, particularly solar, is a significant challenge due to stringent requirements for harmonic mitigation. Voltage source inverters serve as critical interfaces
Muhammad imran +4 more
doaj +1 more source
This article designs and validates a P-Q-based shunt active power filter (SAPF) to mitigate voltage harmonics in EERSA’s 13.2 kV feeder 1500080T03. A CYMDIST feeder model, calibrated with field measurements, reveals worst-case voltage THD up to 9.48% due
Brandon Condemaita, Milton Ruiz
doaj +1 more source