Results 51 to 60 of about 1,008 (177)

DC-link capacitor voltage control for single-phase shunt active power filter with step size error cancellation in self-charging algorithm [PDF]

open access: yes, 2016
This study presents an improved self-charging algorithm by introducing a new feature known as step size error cancellation for better performance of DC-link capacitor voltage control in single-phase shunt active power filter (SAPF).
Abd Rahim, Nasrudin   +4 more
core   +1 more source

Real‐Time Implementation of Unknown Input Observer‐Based State and Unknown Disturbance Estimation for Series Active Filters

open access: yesInternational Journal of Circuit Theory and Applications, Volume 53, Issue 7, Page 3970-3992, July 2025.
For the series active filter (SAF), a combined controller and observer scheme is proposed. Two controllers—state feedback (SFB) and linear quadratic regulator (LQR)—along with state observers, including the Luenberger observer (LO), proportional–integral observer (PIO), and unknown input observer (UIO), have been designed.
Nagulapati Kiran, I. E. S. Naidu
wiley   +1 more source

Control Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review

open access: yesEnergies, 2017
Current harmonics is one of the most significant power quality issues which has attracted tremendous research interest. Shunt active power filter (SAPF) is the best solution to minimize harmonic contamination, but its effectiveness is strictly dependent ...
Yap Hoon   +3 more
doaj   +1 more source

Finite control set model predictive control for a three-phase shunt active power filter with a kalman filter-based estimation [PDF]

open access: yes, 2017
In this paper, the finite control set model predictive control is combined with the vector operation technique to be applied in the control of a three-phase active power filter.
Camacho Santiago, Antonio   +4 more
core   +2 more sources

An Efficient Multi‐Core DSP Power Management Controller

open access: yesEngineering Reports, Volume 7, Issue 4, April 2025.
This work proposes a power management controller for multi‐core DSP architectures, specifically designed for FT‐xDSP. The primary contributions include a clamp request control unit to ensure system stability during asynchronous resets, and a configurable state transition counter that optimizes clock transitions.
Jian Huang   +4 more
wiley   +1 more source

Active and hybrid filters in medium voltage distribution power systems [PDF]

open access: yes, 2010
This paper presents the design of different topologies of active power filters to compensate reactive power and harmonics in the medium voltage level of a distribution power system. One pure active filter and two hybrid topologies, are implemented.
Arnera, Patricia Liliana   +3 more
core   +2 more sources

Active Power Filtering Using the ZDPC Method under Unbalanced and Distorted Grid Voltage Conditions

open access: yesEnergies, 2015
In this paper, we propose a new Zero Direct Power Control (ZDPC) technique for active compensation of harmonics and reactive power, using shunt active power filter (SAPF), based on cancellation of instantaneous active and reactive power disturbances by ...
Kamel Djazia   +3 more
doaj   +1 more source

DFPI-based Control of the DC-bus Voltage and the AC-side Current of a Shunt Active Power Filter [PDF]

open access: yes, 2016
The current paper presents a continuation of an earlier research and purposes to enhance the performances of the studied system. While the double fuzzy PI (DFPI) control was applied only on the DC capacitor bus in a previous work it is applied here also ...
Djeghloud, H. (Hind)   +2 more
core  

Impacts of Nonlinear Loads on the Power Quality of Solar Microgrids and Proposed Mitigation Strategies

open access: yesEnergy Science &Engineering, Volume 13, Issue 4, Page 1960-1982, April 2025.
Nonlinear loads in solar microgrids introduce power quality issues such as harmonics, voltage distortions, and reduced system efficiency. These disturbances negatively impact the stability and performance of microgrid components, leading to increased losses and potential equipment damage.
Exaud Tweve   +2 more
wiley   +1 more source

Power quality enhancement of distribution grid using a photovoltaic based hybrid active power filter with three level converter

open access: yesEnergy Reports, 2023
This paper employs a second-order sequence filter (SOSF) and proportional–integral (PI) controller to control a hybrid active power filter with photovoltaic (HAPF-PV) through three-level neutral point clamped (NPC) converters.
Ehsan Akbari, Abbas Zare Ghaleh Seyyedi
doaj   +1 more source

Home - About - Disclaimer - Privacy