Results 111 to 120 of about 11,947 (254)

Demonstration of Eight-Sensor Sagnac Fiber-Optic Hydrophone Array with Alternative Quadrature Phase Bias and Response Equalization Demodulation Algorithm

open access: yesPhotonics
The Sagnac interferometer-based fiber-optic hydrophone (S-FOH) exhibits a frequency-dependent response, causing the output signal to deviate from the original acoustic signal, with severe cases leading to signal distortion.
Delong Zhao   +7 more
doaj   +1 more source

Analyse des signaux multicomposante à modulation de fréquence linéaire par la transformation de Teager-Huang-Hough [PDF]

open access: yes, 2014
A novel detection approach of linear FM (LFM) signals, with single or multiple components, in the time-frequency plane of Teager-Huang (TH) transform is presented.
BOUDRAA, Abdelouahab   +4 more
core   +1 more source

Mapping Fatty Acid Composition in the Human Knee: Short‐Term Repeatability at 3T

open access: yesJournal of Magnetic Resonance Imaging, EarlyView.
ABSTRACT Background Alterations in periarticular lipid composition are implicated in musculoskeletal diseases, yet short‐term reliability of MRI‐based triglyceride composition mapping in the knee is not fully established. Purpose To evaluate 1‐week repeatability of proton‐density fat fraction (PDFF) and triglyceride fatty‐acid composition—saturated ...
Dimitri Martel   +8 more
wiley   +1 more source

A neural demodulator for quadrature amplitude modulation signals

open access: yesProceedings of International Conference on Neural Networks (ICNN'96), 2002
A neural demodulator is proposed for quadrature amplitude modulation (QAM) signals. It has several important features compared with conventional linear methods. First, necessary functions for the QAM demodulation, including wide-band noise rejection, pulse waveform shaping, and decoding, can be embedded in a single neural network. This means that these
Katsuyoshi Ohnishi, Kenji Nakayama
openaire   +1 more source

Ultra‐High Frequency Ultrasound Imaging and Quantification of Microvascular Flow in Xenograft Renal Cell Carcinoma in an Avian Chorioallantoic Membrane Model

open access: yesJournal of Ultrasound in Medicine, EarlyView.
Patient‐derived xenograft (PDX) tumor models initiated in avian chorioallantoic membranes (CAM) are under investigation to evaluate the effectiveness of therapeutic options with the objective of personalizing treatments. CAM PDXs paired with ultra‐high frequency ultrasound (UHFUS) imaging could potentially constitute prospective high throughput assays ...
Sara Mar   +5 more
wiley   +1 more source

Study of the Characteristics of Second-Order Underdamped Unsaturated Stochastic Resonance System Driven by OFDM Signals

open access: yesApplied Sciences
Aiming at the issue of suboptimal demodulation performance in OFDM signal enhancement processes due to slow response speeds in first-order overdamped stochastic resonance systems, this paper designs an OFDM signal enhancement and demodulation system ...
Gaohui Liu, Dekang Wang
doaj   +1 more source

COMPENSATION OF OUTPUT SIGNAL TEMPERATURE DEPENDENCE IN HOMODYNE DEMODULATION TECHNIQUE FOR PHASE FIBER-OPTIC SENSORS [PDF]

open access: yes, 2015
Modified phase-generated carrier homodyne demodulation technique for fiber-optic sensors is presented. Nowadays phase-generated carrier homodyne demodulation technique is one of the most widespread.
M. Y. Plotnikov   +4 more
core   +1 more source

Scalable Large Field‐of‐view 3D Photoacoustic Ultrasound Imaging With Digital Multiplexing for Human Extremities

open access: yesLaser &Photonics Reviews, EarlyView.
A digitally multiplexed, large‐aperture photoacoustic and ultrasound imaging architecture is presented to overcome the fundamental limited‐view artifact inherent in conventional arrays. By significantly broadening the structural detection coverage, this scalable platform enables high‐fidelity 3D visualization of human extremities within a single ...
Sinyoung Park   +8 more
wiley   +1 more source

Fast Localized Calibration for Spatial‐Spectral Excitation Without Fly‐Back Gradients

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Standard spatial‐spectral excitation pulses apply a fly‐back gradient between sub‐pulses, limiting, for example, how thin the slices can be (> 4 mm). Without fly‐back gradients, slices can be as thin as 1.7 mm but require a phase calibration for the sub‐pulses with inverted gradients due to system imperfections.
Michael Schär   +3 more
wiley   +1 more source

Identification of Optimal Demodulation Frequency Band and Its Application in Fault Diagnosis of Rolling Element Bearings

open access: yes机车电传动, 2019
In order to effectively extract fault impulses of rolling element bearings in the presence of low signal to noise ratio and intense non-Gaussian noise, a new method for identifying optimal demodulation frequency band was presented and applied to fault ...
Bingyan CHEN   +3 more
doaj  

Home - About - Disclaimer - Privacy