Results 1 to 10 of about 6,202 (265)
Abstract A large number of distributed generators access to low resistance grounding system may have great influence on the fault characteristics of single phase ground. In view of low resistance ground active distribution network, the connection mode of Inverter-interfaced Distributed Generators (IIDG) is discussed comprehensively based
Na Wu +5 more
openaire +1 more source
Research of Single-phase Grounding Fault Simulation for Small Current Grounding System
Our country generally uses small current grounding system (the neutral point no direct grounding system). Due to the fault current is too small to identify. So the distribution network operators have been plagued by this kind of fault line selection accuracy. This research establishes simulink model to analyze the fault of single-phase grounding system
Wei-wei GE +4 more
openaire +2 more sources
Paper show methodic of determine of place of single-phase ground fault with intermittent arc on the overhead power line. The informative signs of single-phase ground fault place are determine by values of voltage of the «resonance» frequencies of zero ...
A. I. Fedotov +2 more
doaj +1 more source
Purpose Development of a model for a compensated 6–10 kV network and a methodology for selecting its element parameters based on estimating the minimum level of higher harmonics in the single-phase-to-ground fault current. Methodology. To estimate the
A. E. Shamrai, I.V. Isaiev
doaj +1 more source
There are some problems existing in the traditional grounding mode of the distribution network. To solve them, this paper proposes a flexible grounding method for neutral point.
Han Zeng +8 more
doaj +1 more source
The use of phase voltage modules to select the damaged phase in case of single-phase earth faults
In case of short circuits, the selection of damaged phases always precedes the determination of the damage location. To select the damaged phase, filter selector of the damaged phase are widely used, using symmetrical components of phase currents.
V. A. Shabanov, A. V. Sorokin
doaj +1 more source
Aiming at the problems that the existing arc suppression cabinet technology cannot adjust the zero sequence voltage flexibly and the control and hardware implementation of active arc suppression equipment based on power electronics are difficult, a new ...
Wu Lifang +7 more
doaj +1 more source
The application of 5G-based communication for pilot protection in a distribution network with distributed generators is becoming increasingly widespread, but the existence of a 5G communication transmission data delay adversely affects the rapidity and ...
Deyang Wang +3 more
doaj +1 more source
In ultra-high voltage (UHV) AC transmission systems, single-phase to ground faults account for more than 80 % of all faults. If reclosing is performed blindly under permanent fault conditions after a single-phase to ground fault, the system may suffer ...
Yikai Wang +8 more
doaj +1 more source
Rapid technological development in grid integration of renewable energy (RE) plants has increased the RE penetration level in power utility network. This dramatic change in power scenario challenges the protection and stability of grid.
Om Prakash Mahela +7 more
doaj +1 more source