Identification of Feeder with Single-Phase Ground Fault
2019 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM), 2019Single-phase ground fault in overhead power lines is one of the most usual types of fault in power grids of 6-35 kV. The arc fault generate a spectrum of higher harmonics of voltage and current. This higher harmonics can be the indication of the fault mode. Illegible higher harmonics can be appearing after removing the main harmonic (50 Hz).
Aleksander Fedotov +2 more
openaire +1 more source
Detection of Single-Phase to Ground Faults in Low-Resistance Grounded MV Systems
IEEE Transactions on Power Delivery, 2021The Conventional zero-sequence (ZS) overcurrent protection method exhibits poor performance for single-phase to ground faults (SPGFs) with high impedance in low-resistance grounded systems (LRGSs), a type of medium-voltage (MV) distribution system. Hence, in this study, a novel SPGF detection methodology, designed specifically for LRGSs, is proposed ...
Jiaquan Chen +3 more
openaire +1 more source
Ground-fault loop impedance calculations in single-phase systems
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference, 2013Protection against electric shock in low-voltage installations by automatic disconnection of the supply must be provided in compliance with applicable national or international standards. Such regulations (e.g. National Electrical Code in the U.S., IEC 60364, BS 7671 in the U.K., etc.) take into account the earthing system of the installation, such as ...
Haijun Liu, Massimo Mitolo, Jun Qiu
openaire +1 more source
A new single-phase-to-ground fault-detecting relay
Electrical Engineering, 1942In the application of differential relays the need for a supervising relay which will detect the existence of a single-phase-to-ground fault condition to the exclusion of all others has frequently arisen. Heretofore, the only scheme available has been to utilize a relay energized by zero-sequence quantities. Generally, the relay has been energized by a
openaire +2 more sources
Single-phase grounding fault identification and fault line selection for compensation grid
Proceedings of The 7th International Power Electronics and Motion Control Conference, 2012A new grounding fault line selection method based on small-world network theory is proposed in order to solve the problems existing in grounding fault line selection device of compensation grid, such as that the correct rate of grounding fault line selection is not high and the selection device cannot recognize high-impedance and low-impedance ...
null Chen Zhongren +2 more
openaire +1 more source
A fault location method for single-phase grounding fault in distribution network
The 27th Chinese Control and Decision Conference (2015 CCDC), 2015The single-phase grounding fault is the most common fault among all types of faults in distribution network. It is of great importance to locate the single phase grounding fault accurately and quickly for reducing economic losses. Aiming at the location of single-phase grounding fault in distribution network, this paper puts forward a new fault ...
Kang Zhongjian, Liu Ruiying, Cao Yang
openaire +1 more source
Transient processes at single phase-to-ground faults in combined grounded networks
2012 Electric Power Quality and Supply Reliability, 2012This paper deals with the combined method of neutral grounding when a high-value resistor is continuously connected to a neutral in parallel with a Petersen coil. Monitoring of processes at single phase-to-ground faults was organized in the 6 kV network of the large-scale iron and steel plant.
Andrey Shirkovets +3 more
openaire +1 more source
2020 5th International Conference on Power and Renewable Energy (ICPRE), 2020
The fault characteristics of the small current grounding system are not obvious when the fault occurs. Currently, it is hard to accurately select and locate the ground fault in the small current grounding system. Therefore, in this paper, a scheme of fault grounding line selection and location is proposed based on the characteristic of the zero ...
Kaiji Liao +4 more
openaire +1 more source
The fault characteristics of the small current grounding system are not obvious when the fault occurs. Currently, it is hard to accurately select and locate the ground fault in the small current grounding system. Therefore, in this paper, a scheme of fault grounding line selection and location is proposed based on the characteristic of the zero ...
Kaiji Liao +4 more
openaire +1 more source
Transient Component-Based Distribution Network Single-Phase Ground Fault Location
Applied Mechanics and Materials, 2013The paper study the single-phase ground Fault Location. Which analysis neutral non-effectively grounded distribution network transient characteristics of single-phase. and verify the HHT method accuracy that through the actual system simulation of single-phase ground fault experiments .It proposed the fault localization criterion which is based on ...
Zeng Ping Wang, Jia Liu, Wei Hua Luo
openaire +1 more source
Single-phase grounding test sequence fault location method for small current grounding system
2020 4th International Conference on HVDC (HVDC), 2020A method for Single-phase grounding test sequence fault location method for small current grounding system is proposed, which aims to compensate for the incomplete or faulty signal of the line ground fault signal when the fault area in the line is located in the prior art.
Zhao Haifeng +5 more
openaire +1 more source