The coal mine power supply and distribution system usually adopts the neutral point non-effectively grounded method. Most of the power supply lines in this method use cable lines.
SI Weibin +6 more
doaj +1 more source
The continuous operation of 1000 MW large hydro generators in China is of great value to the implementation of “double carbon strategy” and power grid safety.
Bin Xiong, Long Zhou, Shuye Ding
doaj +1 more source
Fault Characteristic Analysis of Single-Phase Grounding Fault in AC grid of Energy Router in Interacted and Interconnected Micro Grid [PDF]
The energy router composed of double active bridge (DAB) can interconnect multiple voltage level AC distribution network through DC lines to form AC/DC hybrid distribution network.
Sang Zi-xia +5 more
doaj +1 more source
Feasibility analysis of neutral grounding by small reactor of HVDC converter transformer
Nowadays, the scale of power grid is remarkably increasing and there is a continuous reinforcement of AC–DC hybrid systems. Thus, the single-phase grounding fault currents on the AC grid-side of rectifier and inverter stations increase significantly ...
Ensheng Zhao +5 more
doaj +1 more source
Modelling and control of current full compensation system‐based controllable voltage source
Current active suppression technology of arc overvoltage in distribution network has small capacity of controllable voltage source and complex control and cannot flexibly adjust the zero‐sequence voltage of neutral point.
Hongwen Liu +3 more
doaj +1 more source
One-mode component-based fault section location method for mine high-voltage power network
After a single-phase grounding fault occurs in the mine high-voltage power network, it is important to identify the fault section quickly for the safe and stable operation of the mine power network.
ZHAO Jianwen, CHEN Jiali
doaj +1 more source
Single-phase grounding fault line selection method based on zero-sequence current increment
To address single-phase grounding fault line selection problem in small current grounding distribution network, the paper proposes a fault line selection method based on zero-sequence current (ZSC) increment.
Bai Hao
doaj +1 more source
When a single-phase grounding fault occurs in the coal mine 10 kV power supply system, due to the low sampling frequency of the system, the traditional transient line selection method is easy to lose the “line selection information”, and is greatly ...
GUO Runshou, CAO Jiyuan
doaj +1 more source
Design of a mine-used low-voltage leakage protection device
In view of low reliability of leakage protection device of coal mine low-voltage power grid based on line selection principle of zero-sequence power direction, a hardware and software design scheme of mine-used low-voltage leakage protection device was ...
ZHENG Qingle +3 more
doaj +1 more source
Simulation and Research of Non-effectively Grounding Network of Single-phase Ground-fault
Abstract When the non-effectively grounding network of single-phase ground fault happens, the voltage, the current, the zero-sequence voltage and the zero-sequence current have a special change and this problem has been the focus of research attention.
Yunhai Hou, Haoxin Sun, Shuhan Zhang
openaire +1 more source