Results 11 to 20 of about 586,724 (257)

Small-angle scattering and quasiclassical approximation beyond leading order [PDF]

open access: yesPhysics Letters B, 2015
In the present paper we examine the accuracy of the quasiclassical approach on the example of small-angle electron elastic scattering. Using the quasiclassical approach, we derive the differential cross section and the Sherman function for arbitrary ...
P.A. Krachkov, R.N. Lee, A.I. Milstein
doaj   +4 more sources

COMP Report: CPQR technical quality control guidelines for use of positron emission tomography/computed tomography in radiation treatment planning

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Positron emission tomography with x‐ray computed tomography (PET/CT) is increasingly being utilized for radiation treatment planning (RTP). Accurate delivery of RT therefore depends on quality PET/CT data. This study covers quality control (QC) procedures required for PET/CT for diagnostic imaging and incremental QC required for RTP.
Ran Klein   +7 more
wiley   +1 more source

Treatment planning with a 2.5 MV photon beam for radiation therapy

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Purpose The shallow depth of maximum dose and higher dose fall‐off gradient of a 2.5 MV beam along the central axis that is available for imaging on linear accelerators is investigated for treatment of shallow tumors and sparing the organs at risk (OARs) beyond it.
Navid Khaledi   +5 more
wiley   +1 more source

Validation of pencil beam scanning proton therapy with multi‐leaf collimator calculated by a commercial Monte Carlo dose engine

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract This study aimed to evaluate the clinical beam commissioning results and lateral penumbra characteristics of our new pencil beam scanning (PBS) proton therapy using a multi‐leaf collimator (MLC) calculated by use of a commercial Monte Carlo dose engine.
Yuki Tominaga   +5 more
wiley   +1 more source

Accuracy of patient dose estimation in cone beam computed tomography in breast irradiation by size‐specific dose estimates with position correction

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract This study aims to investigate the effects of the position correction of size‐specific dose estimates (SSDE) on patient dose estimation in cone beam computed tomography (CBCT). The relationship between the phantom position and absorbed dose in the right breast was studied using optically stimulated luminescence dosimeters and a simulated human
Hiroyuki Ueno   +3 more
wiley   +1 more source

Practical applications of small-angle neutron scattering. [PDF]

open access: yes, 2013
Recent improvements in beam-line accessibility and technology have led to small-angle neutron scattering (SANS) becoming more frequently applied to materials problems.
Hollamby, MJ
core   +6 more sources

Unitary Scattering Protected by Pseudo-Hermiticity [PDF]

open access: yesChin. Phys. Lett. 39, 037302 (2022), 2022
The Hermitian systems possess unitary scattering; however, the Hermiticity is unnecessary for a unitary scattering although the scattering under the influence of non-Hermiticity is mostly non-unitary. Here we prove that the unitary scattering is protected by certain type of pseudo-Hermiticity and unaffected by the degree of non-Hermiticity.
arxiv   +1 more source

Small Angle Scattering of Polarized Protons [PDF]

open access: yes, 2002
Experiment E950 at AGS, BNL has provided data with high statistics for the left-right asymmetry of proton-carbon elastic scattering in the Coulomb-nuclear interference region of momentum transfer.
Kopeliovich, B. Z.
core   +3 more sources

SANS-1: Small angle neutron scattering

open access: yesJournal of large-scale research facilities JLSRF, 2015
The new small angle scattering instrument SANS-1, jointly operated by the Technische Universität München and GEMS, Helmholtz-Zentrum Geesthacht, has completed commissioning and is in regular user service (Gilles et al., 2006).
André Heinemann, Sebastian Mühlbauer
doaj   +1 more source

Small angle neutron scattering

open access: yesEPJ Web of Conferences, 2015
Small Angle Neutron Scattering (SANS) is a technique that enables to probe the 3-D structure of materials on a typical size range lying from ∼ 1 nm up to ∼ a few 100 nm, the obtained information being statistically averaged on a sample whose volume is ...
Cousin Fabrice
doaj   +1 more source

Home - About - Disclaimer - Privacy