Results 11 to 20 of about 9,522 (169)

False Positive Responses in Standard Automated Perimetry [PDF]

open access: yesAmerican Journal of Ophthalmology, 2022
To analyze the relationship between rates of false positive (FP) responses and standard automated perimetry results.Prospective multicenter cross-sectional study.One hundred twenty-six patients with manifest or suspect glaucoma were tested with Swedish Interactive Thresholding Algorithm (SITA) Standard, SITA Fast, and SITA Faster at each of 2 visits ...
Anders Heijl   +8 more
openaire   +6 more sources

Repeatability of Automated Perimetry: A Comparison between Standard Automated Perimetry with Stimulus Size III and V, Matrix, and Motion Perimetry

open access: yesInvestigative Opthalmology & Visual Science, 2009
Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA ...
Michael, Wall   +3 more
openaire   +4 more sources

The relationship between standard automated perimetry and GDx VCC measurements [PDF]

open access: yesInvestigative Opthalmology & Visual Science, 2004
PURPOSE: To investigate the relationship between retinal light sensitivity measured with standard automated ...
Lemij, H.G. (Hans), Reus, N.J.
core   +3 more sources

Evaluation of Virtual Reality Perimetry and Standard Automated Perimetry in Normal Children. [PDF]

open access: yesTransl Vis Sci Technol, 2023
The Olleyes VisuALL-K is a pediatric videogame-based static threshold perimeter using a virtual reality headset. We determined normal threshold sensitivities for the 24-2 test locations using the virtual reality perimetry (VRP) and also tested patients on the Humphrey Field Analyzer (HFA).
Groth SL   +4 more
europepmc   +3 more sources

Short wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy. [PDF]

open access: yesSci Rep, 2020
AbstractShort wavelength automated perimetry (SWAP) is known for detecting the early reduction of retinal sensitivity (RS) in glaucoma. It’s application in retinal diseases have also been discussed previously. We investigated the difference in RS measured between standard white-on-white automated perimetry (WW) and blue-on-yellow SWAP in central serous
Zhou HP   +8 more
europepmc   +5 more sources

Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma. [PDF]

open access: yesSci Rep, 2022
AbstractThis study aimed to find out the significance of the difference between frequency-doubling technology perimetry (FDT) and standard automated perimetry (SAP) in terms of the detected visual field (VF) damage, and evaluate associated factors to SAP–FDT difference in early glaucoma.
Kim SA, Park CK, Park HL.
europepmc   +4 more sources

Short Wavelength Automated Perimetry, Standard Automated Perimetry, and Optical Coherence Tomography in Dominant Optic Atrophy. [PDF]

open access: yesJ Clin Med
Background: Blue-yellow axis dyschromatopsia is well-known in Autosomal Dominant Optic Atrophy (ADOA) patients, but there were no data on the correlation between retinal structure and short-wavelength automated perimetry (SWAP) values in this pathology.
Lombardo M   +6 more
europepmc   +4 more sources

Circular Contrast Perimetry via Web Application: A Patient Appraisal and Comparison to Standard Automated Perimetry. [PDF]

open access: yesOphthalmol Sci, 2022
The purpose of the study was to compare a novel, 24°, 52-locus online circular contrast perimetry (OCCP) application against standard automated perimetry (SAP) in terms of both diagnostic accuracy and patient attitudes.This was a cross-sectional study.Ninety-five participants (42 controls and 53 open-angle glaucoma patients) were included.Participants ...
Meyerov J   +3 more
europepmc   +4 more sources

Online Circular Contrast Perimetry: A Comparison to Standard Automated Perimetry

open access: yesAsia-Pacific Journal of Ophthalmology, 2023
The aim was to validate and compare the diagnostic accuracy of a novel 24-degree, 52-loci online circular contrast perimetry (OCCP) application to standard automated perimetry (SAP).Prospective cohort study.Two hundred and twenty participants (125 normal controls, 95 open angle glaucoma patients) were included.
Joshua Meyerov   +4 more
openaire   +2 more sources

Octopus 900 Automated Kinetic Perimetry versus Standard Automated Static Perimetry in Glaucoma Practice

open access: yesCurrent Eye Research, 2020
Purpose: The presence of central visual field loss does not infer the extent of peripheral visual field loss. In advanced stage glaucoma, we evaluated whether automated kinetic perimetry provided additional visual field information to that of central static perimetry.
Rowe, Fiona J   +4 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy