Results 51 to 60 of about 153,747 (263)

Giant cell aortitis leading to Stanford type B and type A aortic dissection [PDF]

open access: yesJRSM Open, 2017
Lesson This report provides a rare histological example and the appropriate management of spontaneous aortic dissection secondary to giant cell arteritis.
El-Medany, Ahmed   +4 more
openaire   +2 more sources

Parity‐Dependent THz Harmonic Generation in Electrically Pumped Micro‐Lasers Exploiting Topological Insulator–Metamaterial Gratings

open access: yesAdvanced Materials, EarlyView.
Topological insulator–metamaterials integrated with electrically driven terahertz quantum cascade lasers enable parity‐dependent harmonic generation. Bulk‐dominated Bi2Se3 favors third‐harmonic emission at 9.96 THz, whereas topological‐surface‐state‐dominated Bi2Se3, Bi2Te3, and (Bi,Sb)2Te3 generate strong second harmonics near 6.5 THz.
Alessandra Di Gaspare   +9 more
wiley   +1 more source

Recent Advances of Slip Sensors for Smart Robotics

open access: yesAdvanced Materials Technologies, EarlyView.
This review summarizes recent progress in robotic slip sensors across mechanical, electrical, thermal, optical, magnetic, and acoustic mechanisms, offering a comprehensive reference for the selection of slip sensors in robotic applications. In addition, current challenges and emerging trends are identified to advance the development of robust, adaptive,
Xingyu Zhang   +8 more
wiley   +1 more source

Construction of perioperative nursing quality evaluation index system for thoracic endovascular aortic repair of Stanford type B aortic dissection

open access: yesHuli yanjiu, 2023
ObjectiveTo construct the perioperative nursing quality evaluation index system for thoracic endovascular aortic repair(TEVAR)of Stanford type B aortic dissection, and to provide a basis for the evaluation of specialized nursing quality in the ...
ZHANG Haiyan, LI Yanxin
doaj  

Asymmetry in Skipping Enhances Viability Against Control Input Noise

open access: yesAdvanced Robotics Research, EarlyView.
Quadruped animals use asymmetric galloping gaits at high speeds, yet the functional role of this asymmetry remains unclear. This study shows that left–right asymmetry in touchdown angles enhances robustness to control noise. Using a simple two‐legged locomotion model and viability theory, it demonstrates that asymmetric skipping substantially enlarges ...
Yuichi Ambe, Alvin So, Shinya Aoi
wiley   +1 more source

Real‐Time Holographic Feedback via Mixed Reality Sensorized Laryngoscope Training System Enhances Pediatric Intubation Training

open access: yesAdvanced Robotics Research, EarlyView.
We proposed a Mixed Reality Sensorized Laryngoscope Training System to provide real‐time holographic torque feedback during pediatric endotracheal intubation simulation. Visualization formats are evaluated to reduce tracking error and visual demand.
Jiaqi Li   +5 more
wiley   +1 more source

Continuum Robots in Surgery: From Engineering Design to Clinical Practice

open access: yesAdvanced Robotics Research, EarlyView.
The hyper‐redundant nature of continuum robot structures enables near‐infinite degrees of freedom leading to immense potential for medical applications. This review provides a historical background of continuum robots and novel ideas shaping their progress to current structural design, sensing technology, modeling techniques, and control methods.
Griffin Smith   +6 more
wiley   +1 more source

An On‐Demand Neuromorphic Vision System Enabled by a Multi‐Paradigm Neuromorphic Device and Hierarchical Reconfigurability Designed from Device to System Level

open access: yesAdvanced Science, EarlyView.
An on‐demand ultra‐reconfigurable intelligent vision system with hierarchical reconfigurability from device to system levels is demonstrated. Through co‐design of a multi‐paradigm device, reconfigurable circuits, and adaptive system architecture/algorithms, the system enables seamless switching among spiking, non‐spiking, neuromorphic imaging (NI), and
Biyi Jiang   +7 more
wiley   +1 more source

Interrupted Aortic Arch Complicated with Type A Aortic Dissection in a Young Adult

open access: yesHeart Views
Interrupted aortic arch (IAA) is a congenital anomaly characterized by a discontinuity between the ascending and descending aorta. We present a 27-year-old male patient who had presented with Stanford Type A aortic dissection and was subsequently found ...
Ashish Dua   +3 more
doaj   +1 more source

Phase Diagrams and Piezoelectric Properties of Wurtzite Al1−x−yScxGdyN Heterostructural Alloys

open access: yesAdvanced Science, EarlyView.
This study demonstrates ferroelectricity and piezoelectric properties improvement of quaternary wurtzite Al1−x−yScxGdyN${\rm Al}_{1-x-y}{\rm Sc}_x{\rm Gd}_y{\rm N}$ films, guided by density functional theory calculations. Wurtzite Al1−x−yScxGdyN${\rm Al}_{1-x-y}{\rm Sc}_x{\rm Gd}_y{\rm N}$ films have a high optical bandgap, enhanced piezoelectric ...
Julia L. Martin   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy