Results 51 to 60 of about 416 (173)

AUTOMATIC ADJUSTMENT OF REACTIVE POWER BY FACTS DEVICES UNDER CONDITIONS OF VOLTAGE INSTABILITY IN THE ELECTRIC NETWORK

open access: yesInformatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska, 2023
This article describes the problem of automatic regulation of reactive power using electronic devices FACTS (Flexible AC Transmission Systems): static synchronous compensator (STATCOM) and unified power flow controller (UPFC). With the help of a complex
Mykhailo Burbelo   +6 more
doaj   +1 more source

Multi‐Input Backstepping Control for Transient Stability Enhancement in Power Systems With PMSG‐Based Wind Turbines and UPFC

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
In the paper, first, the modelling of a power system with a Permanent Magnet Synchronous Generator (PMSG), Unified Power Flow Controller (UPFC) and Doubly‐Fed Induction Generator (DFIG) is fully considered. Next, the possible candidate control law and its implementation technique on the power network are examined.
Mohsen Zamani Boroujeni   +3 more
wiley   +1 more source

Multi‐Dimensional Stability Constrained Bi‐Level Topology Optimisation Method for HVDC Systems Embedded in Dense AC Grids

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
1) The typical operational risks and coupling characteristics of the AC/DC hybrid power grid are analyzed in detail. 2) A bi‐Level topology optimization method is designed for HVDC systems embedded in dense AC grids. 3) Considering engineering standards of both security and economy, multi‐dimensional security and stability constraints are incorporated ...
Mingxin Yan   +5 more
wiley   +1 more source

Value‐Based Reinforcement Learning for Inter‐Area Oscillations Mitigation in PV‐Integrated Power Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
Enhanced critic‐only DQN with smoothing enables continuous SVC control for damping inter‐area oscillations. The state selection via participation and residue analysis captures critical key modes. Orthogonal array efficiently tunes hyperparameters with low cost.
Gunawan Dewantoro   +3 more
wiley   +1 more source

Admittance‑Based Two‑Stage Optimisation of GFM‑STATCOM Parameters for Transient Voltage Support in DFIG Wind Farms

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper builds an admittance model for a DFIG‐STATCOM parallel system. Based on the system, the paper provides a method to optimise the control of the STATCOM, which aims to increase the performance of the system during symmetrical faults .
Wenhao Du   +5 more
wiley   +1 more source

Shunt compensation for mitigation of harmonics, voltage sags, and flickers using new STATCOM control scheme

open access: yesEnergy Conversion and Economics, 2022
Voltage sags flickers, and harmonics are major problems associated with power quality and are of concern to power companies and consumers. Therefore, efforts to improve power quality have increased. This study explores the dynamic performance of a static
Mohammed Redha Qader
doaj   +1 more source

A Hybrid‐Frequency Modulation Method for Cascaded H‐Bridge STATCOM With the Hybrid‐Frequency Power Loop

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
To address DC‐side voltage imbalance in star‐connected cascaded H‐bridge STATCOMs under unbalanced grids, a hybrid‐frequency power loop is introduced to enable interphase power transfer. A hybrid‐frequency PWM (HFPWM) method based on voltage vector superposition is proposed, which maintains superior output characteristics for the intermediate‐frequency
Zhendong Ji   +4 more
wiley   +1 more source

Analysis of Balanced and Unbalanced Distribution Systems to Reduce Neutral Currents

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
Exploiting the capability for home‐level rephasing in a strategic manner to address the problem of unbalance from the root level. Performing DG allocation to inject power proportional to the loads present in each phase at the feeder. Usage of reconfiguration to facilitate the distribution system to appear balanced to the transmission system upstream to
Girish Sundararajan   +5 more
wiley   +1 more source

Research on a novel STATCOM based on hybrid cascaded multi-level converter and its coordination control strategy

open access: yesThe Journal of Engineering, 2019
A novel static synchronous compensator (STATCOM) based on hybrid cascaded multi-level converter (HCMC) is presented in this study, i.e HCMC-STATCOM, which combines the advantages of the traditional two-level converter and cascaded H-bridge converter ...
Yi Du   +4 more
doaj   +1 more source

Permanent Fault Identification Scheme for Distribution Feeders Using Detection‐Based Reclosing

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper proposes a novel permanent fault identification scheme based on detection‐based reclosing to mitigate the risks of blind three‐phase reclosing and overcome the sensitivity limitations of existing methods. ABSTRACT To mitigate secondary damage caused by reclosing a distribution line with a permanent fault, a highly sensitive fault property ...
Zhongxue Chang   +3 more
wiley   +1 more source