Results 31 to 40 of about 27,741 (152)
Effective integration of large-scale wind power using PV-STATCOM
Integration of large scale wind farms into the electrical grid poses challenges due to the variable nature of the source of energy and the fact that induction generators, used in the wind turbines, lacking the voltage regulation capability or even, in ...
M.A.H. Rafi, T. Vo, P.H. Nguyen
doaj +1 more source
Power analysis of static VAr compensators [PDF]
Analysis of three-phase loads usually assume them to be three impedances in a star or triangle connection. This is the reason why obtained results can only be considered valid for passive loads, strictly speaking. Analysis leading to the proposal of some static compensators is usually performed in this way, which induces to believe that this ...
Redondo Quintela, Félix +2 more
openaire +2 more sources
This paper proposes a combined approach to determine the optimal allocation of different shunt compensation devices (shunt capacitor, static var compensator, and static synchronous compensator) in power systems.
Salah Kamel, Heba Youssef
doaj +1 more source
IMPROVING POWER SYSTEM QUALITY USING FLEXIBLE AC TRANSMISSION SYSTEMS [PDF]
This paper presents detailed fast control characteristics and continuous compensation capability. Flexible AC Transmission System (FACTS) devices have been researched and adopted in power engineering area. There are so many advantages of FACTS device; it
Ahmed Hassan +2 more
doaj +1 more source
Multistage artificial immune system for static VAR compensator planning
Interconnected network of transmission and distribution lines lead to losses in the system and weakening the voltage stability in the system. Installing Static VAR Compensator (SVC) in power system has known to improve the system by minimizing the total ...
S. Nasir +6 more
semanticscholar +1 more source
Design and Implementation of Correct Operation of Transmission Line Distance Relay in the Presence of SVC under Asymmetrical Faults in Power Systems without Utilizing Communication Systems [PDF]
This paper addresses the design and implementation of correct distance relay operation for transmission lines during single-phase asymmetric faults in the presence of SVC.
Saeed Abazari, Abas Marefat
doaj +1 more source
Análise de estabilidade de geradores de indução utilizados em turbinas eólicas de velocidade fixa
Neste trabalho, analisa-se o desempenho dinâmico de dois métodos para melhorar a estabilidade de turbinas eólicas de velocidade fixa, equipadas com geradores de indução, conectadas em redes de distribuição de energia elétrica, durante contingências no ...
Maurício Barbosa de Camargo Salles +1 more
doaj +1 more source
Comparative Analysis of Reactive Power Compensation Devices in a Real Electric Substation
A constant worldwide growing load stress over a power system compelled the practice of a reactive power injection to ensure an efficient power network.
Hanan Tariq +7 more
doaj +1 more source
This paper presents the impact assessment of distributed generations (DGs) (such as T 2 and T 4 i.e operating at different power factors such as 0.85, 0.90, 0.95 and 0.99 leading and lagging, respectively) and flexible alternating current transmission ...
Bindeshwar Singh +2 more
semanticscholar +1 more source
Application of Static Var Compensator in Songhe Coal Mine
In order to solve problems that traditional stationary reactive var compensator only compensates power factor to some extent and cannot eliminate higher harmonic pollution of power network caused by soft starters of high power loads of coal mine, the ...
DONG Jun, CHEN Tia
doaj

