The Application Study on the Improved Canny Algorithm for Edge Detection in Strain Gauge Image
In order to realize automatic cutting of strain gauge diaphragm, it is needed to detect and identify strain gauge edge. Though classic canny algorithm can detect the edge of strain gauge, it has such problems as low accuracy, being easily influenced by ...
Wei Qin, Juan Li
doaj +1 more source
Stretchable nanocomposites-based strain gauges have received much attention due to their adjustable properties in various applications, including soft robotics, human health monitoring, body motion detection, structural health monitoring, and artificial ...
Seyedmajid Hosseini +2 more
doaj +1 more source
Graphene as a Piezoresistive Material in Strain Sensing Applications
High accuracy measurement of mechanical strain is critical and broadly practiced in several application areas including structural health monitoring, industrial process control, manufacturing, avionics and the automotive industry, to name a few.
Farid Sayar Irani +6 more
doaj +1 more source
Giant gauge factor of Van der Waals material based strain sensors
There is an emergent demand for high-flexibility, high-sensitivity and low-power strain gauges capable of sensing small deformations and vibrations in extreme conditions.
Wenjie Yan +15 more
semanticscholar +1 more source
Decoupled Six-Axis Force-Moment Sensor with a Novel Strain Gauge Arrangement and Error Reduction Techniques. [PDF]
In this study, a novel strain gauge arrangement and error reduction techniques were proposed to minimize crosstalk reading and simultaneously increase sensitivity on a decoupled six-axis force–moment (F/M) sensor.
Kebede GA, Ahmad AR, Lee SC, Lin CY.
europepmc +2 more sources
Ultra‐High Gauge Factor Strain Sensor with Wide‐Range Stretchability
Strain sensors with wide‐range stretchability, good sensitivity, high gauge factor, and reliability are needed for several applications. Herein, stretchable strain sensors capable of operating over multi‐strain range and having an excellent gauge factor ...
Yogeenth Kumaresan +4 more
semanticscholar +1 more source
Feasibility on accurate measurement of non-uniform strain field through contact methods
When straight material filaments do not remain straight after deformation, the strain varies spatially. These spatially varying strain fields arise because of (1) non-uniform distribution of boundary traction, (2) presence of residual stress in the ...
Pratyush Kumar, U. Saravanan
doaj +1 more source
The article reviews the development of the volumetric borehole strain gauge. In response to the current problems of insufficient stability and bandwidth and low calibration accuracy of the volumetric strain gauge, a TY-2B-type small volumetric borehole ...
SUN Yao +5 more
doaj +1 more source
In this study, polydimethylsiloxane (PDMS) and conductive carbon nanoparticles were combined to fabricate a conductive elastomer PDMS (CPDMS). A high sensitive and flexible CPDMS strain sensor is fabricated by using stamping-process based micro ...
Chi-Jui Han +2 more
doaj +1 more source
Interacting Dirac fermions under spatially alternating pseudo-magnetic field: Realization of spontaneous quantum Hall effect [PDF]
Both topological crystalline insulators surfaces and graphene host multi-valley massless Dirac fermions which are not pinned to a high-symmetry point of the Brillouin zone.