Results 151 to 160 of about 512,746 (206)
Some of the next articles are maybe not open access.
Switching overvoltages in motor circuits
IEEE Transactions on Industry Applications, 2001The switching of HV motor circuits in the megawatt range can cause large overvoltages on motor terminals. The amplitude of the resulting voltage spikes depends on breaker type and circuit characteristics. If the amplitude of switching overvoltages exceeds the basic insulation level of the motor, overvoltage protection circuitry should be installed to ...
M. Berth, M. Kung, E.F.D.E. Limbeek
openaire +1 more source
No descrinverter-fed motors are vulnerable to premature insulation failure due to overvoltage stress across stator windings because of antiresonance phenomenon which is characterized by two oscillatory overvoltage responses that manifest at the motor ...
Mohamed Diab, Xibo Yuan
exaly +3 more sources
Simulation of Switching Overvoltages and Validation With Field Tests
IEEE Transactions on Power Delivery, 2018On transmission lines where switching surges are not mitigated with closing resistors and/or surge arresters, high-speed reclosing on a line with trapped charge will produce high overvoltages that have been measured above 3 p.u. Careful simulations of these switching events using available electromagnetic transient (EMT) programs consistently produce ...
M. Cervantes +10 more
openaire +2 more sources
Switching Overvoltage of UHVAC Systems
2017The UHV system is featured by high voltage level and large switching overvoltage amplitude. The increase of the rated voltage and the decrease of the limit standard put forward more rigorous requirements for the limitation measures for the switching overvoltage of the UHV system, and the preventive measures for the EHV system are no longer completely ...
Rongrong Ji, Hao Zhou, Xiujuan Chen
openaire +1 more source
Investigation of IGBT Switching Energy Loss and Peak Overvoltage Using Digital Active Gate Drives [PDF]
This paper presents an experimental investigation of the switching energy loss and peak overvoltage occurring in a half-bridge Insulated Gate Bipolar Transistor (IGBT) converter which is switched using an Active Gate Drive. A range of voltage profiles is
Daniel J Rogers, Gwilliam Iwan Jones
exaly +2 more sources
Overvoltages caused by disconnect-switch operation
Electrical Engineering, 1959RECENTLY field tests were performed at the Tanners Creek Station of the Indiana and Michigan Electric Company to investigate overvoltages which were produced when a 1,360-foot section of 345-kv bus was de-energized by an air-break disconnecting switch.1 The high transient overvoltages not only caused severe duty on connected lightning arresters, but ...
S. B. Griscom +2 more
openaire +1 more source
Switching overvoltages in a three-phase transformer
[1992] Proceedings of the 35th Midwest Symposium on Circuits and Systems, 2003Switching operations to energize or isolate a transformer result in voltages and currents of complex waveshapes in the transformer windings. The surges transferred to the coupled nonenergized windings when one winding of the transformer is energized are discussed.
C.S. Indulkar, M.S. Thomas, P.R. Bijwe
openaire +1 more source
A Laboratory Equipment for Investigating Switching Overvoltages
International Journal of Electrical Engineering & Education, 1983A detailed description is given of a transmission line model and voltage source suitable for demonstrating switching overvoltages associated with overhead line energisation. The model is 3-phase with the supply electronically switched independently in each phase and incorporating switched closing resistors.
D. F. Binns, D. Whitehouse
openaire +1 more source
Limitation of transmission line switching overvoltages
2010 IEEE International Conference on Power and Energy, 2010In this paper switching overvoltages of an actual transmission line are studied. Simulations are executed using Electro Magnetic Transients Program. A comprehensive switching transient study is performed for the Azerbaijan province network in Iran. The purpose of this study is to determine the unnecessary pre-insertion resistors in the UHV network ...
Heresh Seyedi, Smko Golabi, Zaher Abam
openaire +1 more source
Switching Overvoltages, Substations
2018This chapter aims to present switching overvoltage insulation coordination methods for substations. As for transmission lines, switching overvoltages only become important for systems whose nominal system voltage is equal to or greater than 345 kV.
openaire +1 more source

