Results 61 to 70 of about 10,715 (249)

Review and Analysis of Voltage Clamping Circuits With Low Overvoltage Ratios for DC Circuit Breakers

open access: yesIEEE Open Journal of the Industrial Electronics Society
Voltage clamping circuits are critical components in most direct-current circuit breakers (dcCBs) to achieve ultrafast dc fault interruptions and an extended lifetime.
Shuyan Zhao   +4 more
doaj   +1 more source

Integrated Design of 12 kV Intelligent Ring Main Unit With Multi‐Model Fusion and Fault Diagnosis Method

open access: yesEngineering Reports, Volume 8, Issue 1, January 2026.
This article proposes an integrated design method for a 12 kV intelligent ring main unit and constructs a fault diagnosis and isolation model. Firstly, building an integrated hardware platform can significantly improve perception speed and fusion potential.
Rongrong Shan, Jieyun Qiu, Dong Han
wiley   +1 more source

Overvoltage Impact on Internal Insulation Systems of Transformers in Electrical Networks with Vacuum Circuit Breakers

open access: yesEnergies, 2020
Vacuum circuit breakers are increasingly used as switching apparatus in electric power systems. The vacuum circuit breakers (VCBs) have very good operating properties. VCBs are characterized by specific physical phenomena that affect overvoltage exposure
Marek Florkowski   +3 more
doaj   +1 more source

Technical SWOT analysis of decentralised production for low voltage grids in Flanders [PDF]

open access: yes, 2012
The increasing energy prices, combined with high funding by the government, has resulted in a massive integration of decentralised electrical energy production units in Belgium.
Debruyne, Colin   +3 more
core  

About the stabilization of the dendritic structure of GG brand copper powder [PDF]

open access: yes, 2015
In industry copper powder is recieved under constant current load. Surface roughening occurs during evolution of the dendritic particles. It is suggested to create a new impulse of current equal to the initial current density of 3200 A/m2 in order to ...
Darintseva, A. B.   +2 more
core   +2 more sources

Modeling and Control of a Multi‐Energy Microgrid With Wind LVRT and Battery Pre‐Synchronization Strategy

open access: yesEnergy Science &Engineering, Volume 14, Issue 1, Page 266-280, January 2026.
This study establishes a hybrid microgrid model integrating a Doubly Fed Induction Generator (DFIG), a photovoltaic (PV) array, and a battery energy storage system, and proposes a coordinated control framework. The DFIG regulates DC‐bus voltage through the grid‐side converter and performs maximum power tracking via the rotor‐side converter, while the ...
Chunyan Li   +4 more
wiley   +1 more source

Enhancing Resilience and Efficiency in Low‐Voltage Resistive AC Microgrids Through Distributed Control Strategies

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A distributed secondary control strategy for low‐voltage resistive AC microgrids is proposed, where consensus‐based algorithms dynamically adjust both the slope and offset of V‐I droop characteristics. This dual adaptation enables accurate proportional power sharing and effective voltage regulation at the PCC, while ensuring fast transient response and
Afshin Hasani   +2 more
wiley   +1 more source

Active distribution power system with multi-terminal DC links [PDF]

open access: yes, 2015
A fast power restoration operational scheme and relevant stabilizing control is proposed for active distribution power systems with multi-terminal DC network in replacement of the conventional normal open switches. A 9-feeder benchmark distribution power
Chen, Dong, Xu, Lie, Zhang, Wendian
core   +2 more sources

Multi‐Layer MTDC Protection: Design and Simulation Assessment

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This study proposes a novel multi‐layer protection architecture for multi‐terminal DC systems that separates fault current‐limiting and interruption functions. By combining a thyristor‐based fault current limiter with an active resonance circuit breaker, the scheme significantly reduces peak fault currents and di/dt stress, enabling a more compact ...
Jong‐Geon Lee   +3 more
wiley   +1 more source

Tower Air-gaps discharge characteristics and insulation coordination for UHV AC double-circuit line

open access: yesThe Journal of Engineering, 2019
In order to give out inverse V-type insulator tower air-gaps configuration of double-circuit UHV AC power transmission line, different distance air-gaps from high-voltage electrode to tower frame discharge tests of inverse V-string are carried out ...
Huo Feng, Nan Jing, Ye Qiming, Ma Yeming
doaj   +1 more source