Results 121 to 130 of about 134,946 (297)
In order to achieve the polar function of the machine,the corresponding feed drive system is designed.A differential gear structure is used,the corresponding motion synthesis algorithm is developed.The synchronous feed motion of machine U and C axis is ...
曹立宏, 李刚, 王宏
doaj
Effects of bearing deadbands on bearing loads and rotor stability [PDF]
The Jeffcott model of a turbopump which was modified by adding deadband (clearance) effects along with fluid seal forces are currently understood. Equations of motion for the model were written in polar coordinates, and a constant side force was added to
Bukley, A. P., Glaese, J. R.
core +1 more source
Atomic Layer Deposition in Transistors and Monolithic 3D Integration
Transistors are fundamental building blocks of modern electronics. This review summarizes recent progress in atomic layer deposition (ALD) for the synthesis of two‐dimensional (2D) metal oxides and transition‐metal dichalcogenides (TMDCs), with particular emphasis on their enabling role in monolithic three‐dimensional (M3D) integration for next ...
Yue Liu +5 more
wiley +1 more source
Inviscid Simulations of Interacting Flags and Falling Sheets
We present a fluid dynamics video showing simulations of flexible bodies flapping and falling in an inviscid fluid. Vortex sheets are shed from the trailing edges of the bodies according to the Kutta condition.
Alben, Silas
core
Unlocking Photodetection Mode Switching from a Simple Lateral Design
A simple lateral 2D perovskite photodetector capable of switching among transient, continuous, and dual transient/continuous photoresponse modes is achieved by integrating photoconductive effects with capacitive coupling from the SiO2/Si substrate. Such light‐programmable photodetection mode switching enables triple‐channel information transmission and
Zijun (June) Yong +10 more
wiley +1 more source
Mechanical and Electrical Phenotype of hiPSC‐Cardiomyocytes on Fibronectin‐Based Hydrogels
We introduce fibronectin‐based PEG hydrogels with controlled rigidity to enable the culture of iPSC‐derived cardiomyocytes. These substrates offer an alternative to the current culture of these cells on fibronectin‐coated glass, providing enhanced structural and functional behavior. The system provides a more physiologically relevant platform to assess
Ana Da Silva Costa +8 more
wiley +1 more source
Bioprinting Organs—Science or Fiction?—A Review From Students to Students
Bioprinting artificial organs has the potential to revolutionize the medical field. This is a comprehensive review of the bioprinting workflow delving into the latest advancements in bioinks, materials and bioprinting techniques, exploring the critical stages of tissue maturation and functionality.
Nicoletta Murenu +18 more
wiley +1 more source
Synchronization of a Perturbed Satellite Attitude Motion
In the paper, the predictive control method is proposed to control the synchronization of two perturbed satellites attitude motion. Based on delayed feedback control of continuous-time systems combines with the prediction-based method of discrete-time systems, this approach only needs a single controller to realize synchronization, which has ...
openaire +1 more source
Computational Modeling Meets 3D Bioprinting: Emerging Synergies in Cardiovascular Disease Modeling
Emerging advances in three‐dimensional bioprinting and computational modeling are reshaping cardiovascular (CV) research by enabling more realistic, patient‐specific tissue platforms. This review surveys cutting‐edge approaches that merge biomimetic CV constructs with computational simulations to overcome the limitations of traditional models, improve ...
Tanmay Mukherjee +7 more
wiley +1 more source
Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals
Conductive polymer coatings are widely explored to improve the quality of signals recorded with chronically implanted neural electrodes, offering enhanced biocompatibility along with reduced electrode impedance. Combining computational modelling and data from PEDOT:PTS coated and PtIr electrodes in rats, we show that improvements in signal quality with
Karthik Sridhar +4 more
wiley +1 more source

