Results 71 to 80 of about 666,830 (274)
Public Health Outcomes as a Measure of Efficacy of Syringe Exchange Programs [PDF]
Introduction. A syringe exchange is a public health intervention that offers nonjudgmental services to intravenous drug users (IVDU), providing clean syringes in exchange for used syringes.
Corse, Andrew +9 more
core +1 more source
Comparison of regional blood flow values measured by radioactive and fluorescent microspheres [PDF]
Fluorescent microspheres (FM) have become an attractive alternative to radioactive microspheres (RM) for the measurement of regional blood flow (RBF). The aim of the present study was to investigate the comparability of both methods by measuring RBF with
Habler, O. +6 more
core +1 more source
HKUST‐1/TiO2 composite materials show a very high photocatalytic hydrogen evolution rate which increases as a function of the irradiation time until reaching a plateau and even surpasses the performance of the 1%Pt/TiO2 material after three photocatalytic cycles.
Alisha Khan +9 more
wiley +1 more source
Implementation of automated radiopharmaceutical dispenser with integrated radiation shielding
During the preparation of radiopharmaceutical, nuclear medicine staff receive radiation doses to hands much higher than the other parts of the body.
Somsakul Thumvijit, Winit Choiprasert
doaj
Acute and life-threatening remifentanil overdose resulting from the misuse of a syringe pump. [PDF]
In the perioperative setting, syringe pumps are frequently used. They guarantee constant plasma levels of hypnotics, opioids, cardiovascular medication, insulin or other drugs. We present a case in which an inadvertent rapid intravenous injection of 2 mg
Rex, S +3 more
core
This work demonstrates the successful integration of a phenanthroline‐based 2D COF with MnI catalytic sites into a catholyte‐free membrane‐electrode‐assembly cell for CO2 electroreduction. The crystalline COF actively suppresses Mn⁰–Mn⁰ dimerization, achieving a turnover frequency of 617 h⁻¹ at 2.8 V (full‐cell potential), and enabling stable operation.
Laura Spies +8 more
wiley +1 more source
Not sold here: limited access to legally available syringes at pharmacies in Tijuana, Mexico
Background Sterile syringe access is a critical component of HIV prevention programs. Although retail pharmacies provide convenient outlets for syringe access, injection drug users (IDUs) may encounter barriers to syringe purchase even where purchase ...
Brouwer Kimberly C +6 more
doaj +1 more source
Dynamic modelling of hepatitis C virus transmission among people who inject drugs: a methodological review [PDF]
Equipment sharing among people who inject drugs (PWID) is a key risk factor in infection by hepatitis C virus (HCV). Both the effectiveness and cost-effectiveness of interventions aimed at reducing HCV transmission in this population (such as opioid ...
Cousien, Anthony +5 more
core +5 more sources
Micropatterned Biphasic Printed Electrodes for High‐Fidelity on‐Skin Bioelectronics
Micropatterned biphasic printed electrodes achieve unprecedented skin conformity and low impedance by combining liquid‐metal droplets with microstructured 3D lattices. This scalable approach enables high‐fidelity detection of ECG, EMG, and EEG signals, including alpha rhythms from the forehead, with long‐term comfort and stability.
Manuel Reis Carneiro +4 more
wiley +1 more source
5.0.C.1 Hands-on Gas Law Experiments [PDF]
WELCOME to WINDOWS on the INQUIRY CLASSROOM! You have landed on a piece of a National Science Foundation Project (DUE 1245730) directed by Professor Chris Bauer, Chemistry Department, University of New Hampshire.
Bauer, Chris F.
core +1 more source

