Two-grating Talbot bands spectral-domain interferometer [PDF]
A configuration for Talbot bands is presented in which two tilted gratings replace the splitter normally used for recombining the signals from the two interferometer arms. The two optical beams from the interferometer are launched by two fiber leads tightly brought together in the front focal plane of a collimating lens.
Manuel Jorge M. Marques +2 more
core +6 more sources
Implementing dark-field contrast imaging in computer tomography with simple setup Talbot-Lau-Interferometer [PDF]
Josephine Gutekunst +4 more
doaj +2 more sources
Quantifying grating defects in X-ray Talbot-Lau interferometry through a comparative study of two fabrication techniques [PDF]
The performance of an X-ray grating interferometry system depends on the geometry and quality of the gratings. Fabrication of micrometer-pitch high-aspect-ratio gold gratings, which are essential for measuring small refraction angles at higher energies ...
Alexandre Pereira +8 more
doaj +2 more sources
Development of x-ray phase tomographic microscope based on Talbot interferometer at BL37XU, SPring-8
An x-ray phase tomographic microscope has been developed by optimizing the optical system for 9-keV synchrotron x rays at BL37XU, SPring-8, Japan. The system consists of a full-field x-ray imaging microscope and a Talbot interferometer.
Hidekazu Takano +6 more
doaj +2 more sources
Segmentation of breast tumors using imaging techniques remains a critical challenge in medical diagnostics, with limitations in contrast and resolution affecting early detection.
Ionut-Cristian Ciobanu +3 more
doaj +2 more sources
Moiré artifact reduction in grating interferometry using multiple harmonics and total variation regularization [PDF]
X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung imaging. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures how a patient
Hunter C. Meyer +9 more
doaj +2 more sources
Adaptive filtering method for reducing signal saturation induced artifacts in X-ray dark-field tomography [PDF]
X-ray dark-field imaging provides information of an object based on its small-angle scattering properties. Dark-field contrast originates from differences in the strength of scattering from micron and sub-micron sized structures in the object.
Henrik Mäkinen +2 more
doaj +2 more sources
An electron Talbot interferometer
The Talbot effect, in which a wave imprinted with transverse periodicity reconstructs itself at regular intervals, is a diffraction phenomenon that occurs in many physical systems. Here we present the first observation of the Talbot effect for electron de Broglie waves behind a nanofabricated transmission grating.
Benjamin J McMorran
exaly +3 more sources
The choice of an autocorrelation length in dark-field lung imaging [PDF]
Respiratory diseases are one of the most common causes of death, and their early detection is crucial for prompt treatment. X-ray dark-field radiography (XDFR) is a promising tool to image objects with unresolved micro-structures such as lungs.
Simon Spindler +8 more
doaj +2 more sources
X-ray phase-contrast imaging is a promising method for medical imaging and non-destructive testing. Information about the attenuation, small-angle scattering and phase-shifting properties of an object can be gained simultaneously in three image ...
Maria Seifert +8 more
doaj +2 more sources