Static VAr Compensators can provide significant improvement in power system stability. Phasor Measurement Units are used in combination with SVCs for fast and reliable control of its operation. By combining the VAr control and Voltage Regulation control methods of the SVC, superior performance is obtained.
Faris Alsalem, Ayman Faza
wiley +1 more source
Static voltage stability margin enhancement using STATCOM, TCSC and SSSC
In this paper, voltage stability assessment with appropriate representations of STATCOM, TCSC and SSSC is investigated and compared in the modified IEEE 14-bus test system.
Lee, K. Y. +2 more
core +1 more source
The primary goals of employing series flexible ac transmission system (FACTS) in automatic generation control (AGC) studies of interconnected power systems are mitigating area frequency and tie-line power oscillations.
Javad Morsali +2 more
doaj +1 more source
Series and Shunt Reactive compensation can be used to improve voltage stability. The L‐index and Fast Voltage Stability Index are used to evaluate stability. Cost of reactive compensation is included directly in the optimization process. Multi‐objective optimization determines the optimal sizing of FACTS devices.
Rawan Abu Zeitawyeh, Ayman Faza
wiley +1 more source
Sistemas de trasmisión flexible en corriente alterna
En el presente trabajo se describe, a grandes rasgos, qué son los Sistemas de Transmisión Flexibles en Corriente Alterna, mejor conocidos como dispositivos FACTS.
Francisco Pérez
doaj
Orthogonal Multi‐swarm Greedy Selection Sine Cosine Algorithm (OMGSCA) effectively optimizes FACTS placement and sizing in wind‐integrated power systems, reducing operational costs and power losses while enhancing grid stability. Tested on the IEEE 30‐bus system, OMGSCA outperforms traditional methods, demonstrating superior exploration, exploitation ...
Sunilkumar P. Agrawal +6 more
wiley +1 more source
Block diagram of the TCSC POD controller.
Block diagram of the TCSC POD controller.
Azah Mohamed (844453) +3 more
core +1 more source
ABSTRACT Reactive power compensation is now a challenging issue in maintaining adequate power quality and improving the performance of the transmission system. Many researchers have focused on the behavior of voltage in the unbalanced state, and the majority of the studies have been done with STATCOM. In this study, the increasing power demand in power
H. Feza Carlak, Ergin Kayar
wiley +1 more source
Inrecent electrical power networks a number of failures due to overloading of the transmission lines, stability problems, mismatch in supply and demand, narrow scope for expanding the transmission network and other issues like global warming ...
M. Rambabu +2 more
doaj +1 more source
The impedance sensitivity of the doubly‐fed induction generator (DFIG) grid‐connected system with series compensation is analysed using the Morris method and the extended Fourier amplitude sensitivity test (EFAST). A cooperative optimisation approach is proposed to adjust high‐sensitivity parameters, thereby suppressing sub‐synchronous oscillations ...
Gaojun Meng +5 more
wiley +1 more source