Results 71 to 80 of about 2,179 (221)

Static VAr Compensator Control Using Phasor Measurement Unit Feedback Signals for Voltage Stability Improvement in Power Systems

open access: yesEnergy Science &Engineering, Volume 13, Issue 7, Page 3569-3587, July 2025.
Static VAr Compensators can provide significant improvement in power system stability. Phasor Measurement Units are used in combination with SVCs for fast and reliable control of its operation. By combining the VAr control and Voltage Regulation control methods of the SVC, superior performance is obtained.
Faris Alsalem, Ayman Faza
wiley   +1 more source

Static voltage stability margin enhancement using STATCOM, TCSC and SSSC

open access: yes, 2005
In this paper, voltage stability assessment with appropriate representations of STATCOM, TCSC and SSSC is investigated and compared in the modified IEEE 14-bus test system.
Lee, K. Y.   +2 more
core   +1 more source

Performance comparison of TCSC with TCPS and SSSC controllers in AGC of realistic interconnected multi-source power system

open access: yesAin Shams Engineering Journal, 2016
The primary goals of employing series flexible ac transmission system (FACTS) in automatic generation control (AGC) studies of interconnected power systems are mitigating area frequency and tie-line power oscillations.
Javad Morsali   +2 more
doaj   +1 more source

Optimal Reactive Power Planning Using FACTS Devices for Voltage Stability Enhancement in Power Transmission Systems

open access: yesEnergy Science &Engineering, Volume 13, Issue 6, Page 2720-2756, June 2025.
Series and Shunt Reactive compensation can be used to improve voltage stability. The L‐index and Fast Voltage Stability Index are used to evaluate stability. Cost of reactive compensation is included directly in the optimization process. Multi‐objective optimization determines the optimal sizing of FACTS devices.
Rawan Abu Zeitawyeh, Ayman Faza
wiley   +1 more source

Sistemas de trasmisión flexible en corriente alterna

open access: yesPrisma Tecnológico, 2016
En el presente trabajo se describe, a grandes rasgos, qué son los Sistemas de Transmisión Flexibles en Corriente Alterna, mejor conocidos como dispositivos FACTS.
Francisco Pérez
doaj  

Orthogonal Multi‐Swarm Greedy Selection Based Sine Cosine Algorithm for Optimal FACTS Placement in Uncertain Wind Integrated Scenario Based Power Systems

open access: yesEngineering Reports, Volume 7, Issue 5, May 2025.
Orthogonal Multi‐swarm Greedy Selection Sine Cosine Algorithm (OMGSCA) effectively optimizes FACTS placement and sizing in wind‐integrated power systems, reducing operational costs and power losses while enhancing grid stability. Tested on the IEEE 30‐bus system, OMGSCA outperforms traditional methods, demonstrating superior exploration, exploitation ...
Sunilkumar P. Agrawal   +6 more
wiley   +1 more source

Block diagram of the TCSC POD controller.

open access: yes, 2016
Block diagram of the TCSC POD controller.
Azah Mohamed (844453)   +3 more
core   +1 more source

Volt/VAr Regulation of the West Mediterranean Regional Electrical Grids Using SVC/STATCOM Devices With Neural Network Algorithms

open access: yesWind Energy, Volume 28, Issue 2, February 2025.
ABSTRACT Reactive power compensation is now a challenging issue in maintaining adequate power quality and improving the performance of the transmission system. Many researchers have focused on the behavior of voltage in the unbalanced state, and the majority of the studies have been done with STATCOM. In this study, the increasing power demand in power
H. Feza Carlak, Ergin Kayar
wiley   +1 more source

Optimal Power Flow of Integrated Renewable Energy System using a Thyristor Controlled SeriesCompensator and a Grey-Wolf Algorithm

open access: yesEnergies, 2019
Inrecent electrical power networks a number of failures due to overloading of the transmission lines, stability problems, mismatch in supply and demand, narrow scope for expanding the transmission network and other issues like global warming ...
M. Rambabu   +2 more
doaj   +1 more source

Sub‐Synchronous Oscillation Suppression Strategy for DFIG Based on Morris‐EFAST Global Sensitivity Analysis and Multi‐Parameter Co‐Optimisation

open access: yesIET Electric Power Applications, Volume 19, Issue 1, January/December 2025.
The impedance sensitivity of the doubly‐fed induction generator (DFIG) grid‐connected system with series compensation is analysed using the Morris method and the extended Fourier amplitude sensitivity test (EFAST). A cooperative optimisation approach is proposed to adjust high‐sensitivity parameters, thereby suppressing sub‐synchronous oscillations ...
Gaojun Meng   +5 more
wiley   +1 more source