Results 61 to 70 of about 24,923 (301)
The Effect of VEGF121 on TEER in TM Cells.
The Effect of VEGF121 on TEER in TM Cells.
Tomokazu Fujimoto (709192) +4 more
core +1 more source
Changes in TEER following iAsIII or MMAIII exposure.
TEER was measured at 6 h and 24 h after exposure to iAsIII (1, 10, and 20 μM) or MMAIII (0.1, 1, and 2 μM). The %TEER was expressed as 100% of the mean of the control TEER value (100%). Results are presented as mean ± SD (n = 4).
Ayako Takata (7526720) +2 more
core +1 more source
n‐Type Polymer Radio Frequency Rectifiers Operating at 18.5 GHz
Combining an n‐doped polymer semiconductor with wafer‐scale asymmetric planar electrodes featuring work function‐engineered contacts yields radio‐frequency diodes and rectifying circuits operating at up to 18.5 GHz. The devices combine scalable manufacturing with an operating frequency previously unattainable by large‐area organic electronics ...
Lazaros Panagiotidis +19 more
wiley +1 more source
Background: Mitral transcatheter edge-to-edge repair (M-TEER) is a treatment option for patients with symptomatic mitral regurgitation (MR). The real-world experience with M-TEER in Canada has not been reported previously.
Shamir R. Mehta, MD, MSc +18 more
doaj +1 more source
A significant inverse correlation was observed between FITC-dextran and TEER using the bEnd.3 cells (Pearson r = -0.77, pA), and between sodium fluorescein and TEER while using the ihBMECs (Pearson r = -0.73, pB).
Annlia Paganini-Hill (11216199) +5 more
core +1 more source
The interfacial spin‐orbit interaction in single‐crystalline Fe1−xCox thin films grown on GaAs(001) can be continuously tuned via alloying. Using spin‐orbit ferromagnetic resonance, the authors find that the interfacial spin‐orbit fields exhibit a nonmonotonic dependence on Co concentration, with a minimum at 20% Co. ABSTRACT The discovery of intrinsic
Hongrui Lao +9 more
wiley +1 more source
Capillary-based TEER measurements are affected by parasitic capacitances that distort the impedance spectrum and compromise reliable determination of barrier resistance of 3D cell structures, e.g. organoids.
Weisgerber Marie-Claire +3 more
doaj +1 more source
Background: Hemodynamic impact of residual mitral regurgitation (MR) after transcatheter edge-to-edge repair (TEER) is not always univocally measured by transesophageal echocardiographic (TEE) assessment alone.
Antonio Maria Leone, MD, PhD +15 more
doaj +1 more source
Strong Fully Reprocessable Engineered Wood Composites
Engineering a hyperbranched adhesive with complementary imine‐bond and hydrogen‐bond networks, combining it with wood particles to fabricate the wood composite (WP/HTP) under mild hot‐pressing conditions. The WP/HTP exhibits 100% mechanical strength recovery after three cycles of reprocessing, and the reprocessed modulus of rupture (MOR) and modulus of
Xilin Zhang +9 more
wiley +1 more source
Trans-epithelial electrical resistance (TEER) is a widely accepted technique to monitor the integrity of tight junction proteins and barrier function of epithelial cells, yet it is a highly variable, costly, and labor-intensive experiment.
Hannah K. Piper +2 more
doaj +1 more source

