Results 201 to 210 of about 678,102 (350)

Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka   +6 more
wiley   +1 more source

The role of therapeutic drug monitoring in treatment of HIV infection [PDF]

open access: green, 2001
David Back   +3 more
openalex   +1 more source

Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki   +9 more
wiley   +1 more source

Geometric and dosimetric evaluation of a commercial AI auto‐contouring tool on multiple anatomical sites in CT scans

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into
Robert N. Finnegan   +6 more
wiley   +1 more source

Dosimetric effect of silicone‐based gel on skin surface during volumetric modulated arc therapy for breast cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to quantify and compare the dosimetric effects of varying thicknesses of StrataXRT, a silicone‐based gel, and other topical agents on the skin surface during volumetric modulated arc therapy (VMAT) for breast cancer.
Tenyoh Suzuki   +13 more
wiley   +1 more source

Quantification and dosimetric impact of intra‐fractional bladder changes during CBCT‐guided online adaptive radiotherapy for pelvic cancer treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study quantitatively evaluates bladder changes and their dosimetric impact during the on‐couch adaptive process on a commercial CBCT‐based online adaptive radiotherapy (CT‐gART) platform. Methods Data from 183 fractions of ten patients receiving online ART for pelvic cancers were analyzed retrospectively.
Ingrid Valencia Lozano   +7 more
wiley   +1 more source

Therapeutic drug monitoring in Parkinson's disease. [PDF]

open access: yesJ Neural Transm (Vienna)
Müller T   +5 more
europepmc   +1 more source

A Case Report of Hemodialysis Patient with Successful Determination of Pilsicainide and Digoxin Dosage by Therapeutic Drug Monitoring.

open access: bronze, 2000
MEGUMI MORII   +7 more
openalex   +2 more sources

Evaluation of dosimetric and spatial accuracy of a virtual cone technique for radiosurgery using linac‐integrated CBCT‐based polymer gel dosimetry

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy