Design of a realistic PET-CT-MRI phantom [PDF]
The validation of the PET image quality of new PET-MRI systems should be done against the image quality of currently available PET-CT systems. This includes the validation of new attenuation correction methods.
Espana Palomares, Samuel +4 more
core +1 more source
Introduction: Medical imaging-based triage is critical for ensuring medical treatment is timely and prioritized. However, without proper image collection and interpretation, triage decisions can be hard to make.
Sofia I. Hernandez-Torres +3 more
doaj +1 more source
EchoFusion: Tracking and Reconstruction of Objects in 4D Freehand Ultrasound Imaging without External Trackers [PDF]
Ultrasound (US) is the most widely used fetal imaging technique. However, US images have limited capture range, and suffer from view dependent artefacts such as acoustic shadows. Compounding of overlapping 3D US acquisitions into a high-resolution volume
Gomez, Alberto +13 more
core +2 more sources
Background: Phantom is very important in radiodiagnostic teaching method, especially in the laboratory of radiography. Exposing object in making radiograph have to consider the amount of radiation which is received by the object.
Muhammad Sofyan +2 more
doaj +1 more source
Emergency medicine in austere environments rely on ultrasound imaging as an essential diagnostic tool. Without extensive training, identifying abnormalities such as shrapnel embedded in tissue, is challenging.
Eric J. Snider +3 more
doaj +1 more source
Feasibility of Imaging Tissue Electrical Conductivity by Switching Field Gradients with MRI. [PDF]
Tissue conductivity is a biophysical marker of tissue structure and physiology. Present methods of measuring tissue conductivity are limited. Electrical impedance tomography, and magnetic resonance electrical impedance tomography rely on passing external
Gibbs, Eric, Liu, Chunlei
core +2 more sources
Radiation dose verification using real tissue phantom in modern radiotherapy techniques
In vitro dosimetric verification prior to patient treatment has a key role in accurate and precision radiotherapy treatment delivery. Most of commercially available dosimetric phantoms have almost homogeneous density throughout their volume, while real ...
Om Prakash Gurjar +5 more
doaj +1 more source
Filament material evaluation for breast phantom fabrication using three-dimensional printing [PDF]
In this study, a method of directly evaluating the dose received by the highly radiation-sensitive mammary gland during mammography was investigated, and a corresponding breast phantom was produced that expresses a mammary gland, as an ...
Lee Jin-Soo +5 more
doaj +1 more source
Air kerma to H-P(3) conversion coefficients for IEC 61267 RQR X-RAY radiation qualities: application to dose monitoring of the lens of the eye in medical diagnostics [PDF]
Recent studies highlight the fact that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens monitoring could be required for these workers.
Duch Guillen, María Amor +3 more
core +2 more sources
Quantitative imaging: systematic review of perfusion/flow phantoms
Background We aimed at reviewing design and realisation of perfusion/flow phantoms for validating quantitative perfusion imaging (PI) applications to encourage best practices.
Marije E. Kamphuis +3 more
doaj +1 more source