Results 111 to 120 of about 8,398 (168)
116. Study of TLD Dosimetry : 1 : TLD phosphers characteristics and reprodusibility
openaire +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Response of TLD-600/TLD-700 and CR-39 to Neutrons for Medical Dosimetry
Luminescence, 2021AbstractIn this study, thermoluminescence detectors (TLD)‐600 and TLD‐700 were used under different conditions to study neutron dosimetry for its application in medical dosimetry as albedo dosimeters. 6LiF has a high cross‐section for neutrons and is more sensitive to neutrons than to gamma radiation.
Sanjay J Dhoble +2 more
exaly +3 more sources
ANALYTICAL SIMULATION OF TLD AND ASSESSING THE EFFECTS OF TLD ON THE RESIDUAL DISPLACEMENT
Various control systems have been implemented to mitigate the effects of earthquakes on buildings, aiming to reduce the kinetic energy generated by dynamic activity caused by earthquakes and wind. Among these systems, Tuned Mass Dampers (TMD) and Tuned Liquid Dampers (TLD) serve as cost-effective and practical passive control mechanisms.
Dağ, Birkan, Börekçi, Muzaffer
core +4 more sources
The Use of LiF (TLD-100) as an Out-of-Field Dosimeter
Company, Solon, OH) responds not only to photons and electrons, but also to neutrons that are produced during high-energy therapies. As a result, TLD-100 measurements outside of the treatment field are suspect when high-energy radiation is used. Although
David Followill +2 more
exaly +1 more source
Medical Physics, 1983
A computerized thermoluminescent (TL) readout technique is presented which considerably improves the precision of dose readout and facilitates the dose information management and storage. The technique is relatively simple and it involves an interface between a commercially available thermoluminescent dosimetry (TLD) analyzer and a minicomputer.
C, Pla, E B, Podgorsak
openaire +2 more sources
A computerized thermoluminescent (TL) readout technique is presented which considerably improves the precision of dose readout and facilitates the dose information management and storage. The technique is relatively simple and it involves an interface between a commercially available thermoluminescent dosimetry (TLD) analyzer and a minicomputer.
C, Pla, E B, Podgorsak
openaire +2 more sources
The anti-viral properties of a small (≈1 kDa), novel Ru(II) photo dynamic compound (PDC), referred to as TLD-1433 (Ruvidar™), are presented. TLD-1433 had previously been demonstrated to exert strong anti-bacterial and anti-cancer properties. We evaluated
Kathleen Glover +2 more
exaly +3 more sources
Implementing Web Classification for TLDs
2015 IEEE/WIC/ACM International Conference on Web Intelligence and Intelligent Agent Technology (WI-IAT), 2015On the market there are many commercial web classification services and a few publicly available web directory services. Unfortunately they mostly focus on English-speaking web sites, making them unsuitable for other languages in terms of classification reliability and coverage.
L Deri +5 more
openaire +4 more sources
Physics in Medicine & Biology, 1971
Since all of the commercially-available readers are manually operated, measurements with thermoluminescent dosemeters (TLD) are time-consuming and require the undivided attention of the operator for an average of a minimum of one minute per reading. Thus when TLD's are to be used on a large scale, some form of automation is indicated.
M, Kartha, J C, MacDonald
openaire +2 more sources
Since all of the commercially-available readers are manually operated, measurements with thermoluminescent dosemeters (TLD) are time-consuming and require the undivided attention of the operator for an average of a minimum of one minute per reading. Thus when TLD's are to be used on a large scale, some form of automation is indicated.
M, Kartha, J C, MacDonald
openaire +2 more sources
Factors affecting the precision of TLD dose measurements using an automatic TLD reader
Physics in Medicine and Biology, 1995An increase in the variability of TLD dose measurements prompted a study of the precision of dose measurements with a Rialto automatic TLD reader. It was found that readings with the same chip measured using two different trays could differ by as much as 7%.
J J, Wood, W P, Mayles
openaire +2 more sources
Physics in Medicine and Biology, 2004
To improve the performance of mono-extruded TLD threads as a dosimetric thermoluminescent tool (French Patent 9903729), a new process was developed by co-extrusion methodology leading to threads of 600 microm diameter with a 50 microm homogeneous polypropylene sheath.
D, Jarnet +6 more
openaire +2 more sources
To improve the performance of mono-extruded TLD threads as a dosimetric thermoluminescent tool (French Patent 9903729), a new process was developed by co-extrusion methodology leading to threads of 600 microm diameter with a 50 microm homogeneous polypropylene sheath.
D, Jarnet +6 more
openaire +2 more sources

