Results 121 to 130 of about 8,398 (168)
Some of the next articles are maybe not open access.

TLD patient monitoring

The British Journal of Radiology, 1987
Thermoluminescent dosemeters (TLDs) provide a valuable means of measuring dose distributions in clinical practice. A problem arises, however, in handling, labelling and positioning the individual dosemeters, which must be kept as clean as possible at all times.
openaire   +2 more sources

A Comparison of TLD and Film for Personnel Dosimetry

Health Physics, 1966
Abstract The film badge is today the most widely used personnel monitoring device for want of a more reliable and accurate system. Recent evaluations of the performance of the available commercial film badge services report a wide variation in both the accuracy and consistency of the reported exposures.
N, Suntharalingam, J R, Cameron
openaire   +2 more sources

Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring

Radiation Measurements, 2008
Abstract In this work the results aimed at assessing the performance of two types of LiF detectors, TLD-100 and TLD-100H, used in the context of extremity dosimetry are presented. Each detector variety was studied for reproducibility, batch homogeneity, residual dose, linearity and energy dependence using, when appropriate, the 90 Sr/ 90 Y radiation
L. Freire   +4 more
openaire   +1 more source

Luminescence Emission of Natural Fluorite and Synthetic CaF2:Mn (TLD-400)

open access: yesRadiation Physics and Chemistry, 2016
© 2015 Elsevier Ltd. The luminescence properties of natural white fluorite indicate that it could be employed as radiation dosimeter similarly to synthetic CaF2:Mn (TLD-400).
Mustafa Topaksu   +2 more
exaly   +2 more sources

A TLD System for Environmental Monitoring

Radiation Protection Dosimetry, 1996
A multi-element dosemeter system for environmental monitoring has been designed. It consists of three solid sintered CaSO 4 :Dy (or CaSO 4 :Tm) properly filtered, and of one low Z, MgB 4 O 7 :Dy,Na TL detectors. This TL dosemeter system is shown to meet all specified criteria and provides the accurate dosimetry required for environmental monitoring ...
openaire   +2 more sources

Influence of the Mn-dopant on the TLD-system CaF2 : Dy(TLD-200)

Nuclear Instruments and Methods, 1980
Abstract Systematic investigations (ESR, IR, electron excited optical emission, glow curve analysis) of the centers involved in the TL-process of commercially available CaF 2 : Dy (TLD-200) and crystals grown by a modified Bridgman-Stockbarger method doped with Dy and Mn are described and the results are discussed.
Norbert Vana   +3 more
openaire   +1 more source

Self-shielding factors for TLD-600 and TLD-100 in an isotropic flux of thermal neutrons

Physics in Medicine & Biology, 1976
Monte Carlo calculations have been carried out to determine the absorption probability (and consequently the self-shielding factor) for an isotropic flux of neutrons impinging on different sized cylindrical samples of TLD-100 and TLD-600.
Y S, Horowitz, A, Dubi, B B, Shahar
openaire   +2 more sources

Low Pre- and Post-Irradiation Fading of LiF:Mg, Ti (TLD-100, TLD-600, TLD-700) Using a Preheat Technique

Radiation Protection Dosimetry, 1996
High pre- and post-irradiation fading prevents the attainment of high accuracy in dosimetry measurements, especially in routine dosimetry when the exact duration and time of exposure are not known. An attempt was made at the Soreq Dosimetry Centre to reduce the fading following or preceding gamma radiation, by employing a high post-irradiation preheat ...
T. Izak-Biran   +3 more
openaire   +1 more source

Multivariate analysis of TLD orientation effects

Medical Physics, 1980
The effect of orientation on extruded thermoluminescent dosimeters has been investigated. TLD's placed on the surface and within a phantom were exposed separately to five diagnostic beam qualities and to 60Co γ rays. The resulting data were subjected to analysis of variance and examined for significant correlations.
B R, Archer, S C, Bushong, J I, Thornby
openaire   +2 more sources

An improved TLD target tracking algorithm

2016 IEEE International Conference on Information and Automation (ICIA), 2016
Target tracking has always been a hot research topic in the field of computer vision. Tracking-Learning-Detection (TLD) is a new algorithm for online learning tracking proposed by Zdenek Kalal. In the algorithm, the computation consuming of detection module is relatively large.
Tao Xu   +4 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy