Results 21 to 30 of about 2,327,371 (190)

Laser-induced ultrasonic measurements for the detection and reconstruction of surface defects

open access: yesActa Acustica, 2021
Laser-induced ultrasonic measurement is a non-contact non-destructive technology that can be employed for the testing and assessment of surface defects.
Qian Feiming   +5 more
doaj   +1 more source

Optimal Design of Sparse Array for Ultrasonic Total Focusing Method by Binary Particle Swarm Optimization

open access: yesIEEE Access, 2020
Ultrasonic phased array technology is used in various fields. Traditional full phased arrays place elements in every position of a uniform lattice with half-wavelength spacing between the lattice points, so the hardware cost is very high.
Han Zhang   +3 more
doaj   +1 more source

Laser induced ultrasonic phased array using Full Matrix Capture data acquisition and Total Focusing Method [PDF]

open access: yes, 2015
Laser based ultrasound is a technique where a short pulsed laser is used to generate ultrasound and optical interferometry is used in order to detect the signal.
Clark, Matt   +2 more
core   +4 more sources

Multi-Mode Total Focusing Method (MTFM) to Detect High-Temperature Hydrogen Attack (HTHA) – A Review

open access: yesJournal of Materials Exploration and Findings, 2023
High temperature hydrogen attack (HTHA) is a commonly observed harm component in carbon steels exposed to high temperature and pressure in a hydrogen-rich environment. Hydrogen together with carbon responds to produce methane.
Anjar Oktikawati   +2 more
doaj   +1 more source

Ultrasonic phased array total focusing method based on sparse deconvolution [PDF]

open access: yesProceedings of Meetings on Acoustics, 2018
Ultrasonic phased array total focusing method (TFM) has been widely used in the field of non-destructive testing (NDT) as an advances post-processing imaging algorithm. It shows great potential in defect detection and characterization. However, due to the small number of excitation elements and large amount of collecting data, its temporal resolution ...
Bei Yu   +4 more
openaire   +1 more source

Space Optimized Plane Wave Imaging for Fast Ultrasonic Inspection with Small Active Aperture: Simulation and Experiment

open access: yesSensors, 2020
Plane wave imaging (PWI) is attracting more attention in industrial nondestructive testing and evaluation (NDT&E). To further improve imaging quality and reduce reconstruction time in ultrasonic imaging with a limited active aperture, an optimized PWI ...
Hao Sui   +3 more
doaj   +1 more source

Fighting against fast speckle decorrelation for light focusing inside live tissue by photon frequency shifting [PDF]

open access: yes, 2020
Light focusing inside live tissue by digital optical phase conjugation (DOPC) has drawn increasing interest due to its potential biomedical applications in optogenetics, microsurgery, phototherapy, and deep-tissue imaging.
Cheng, Zhongtao   +5 more
core   +1 more source

Total Focusing Method (TFM) and Phase Coherence Imaging (PCI) applied to various industrial cases

open access: yese-Journal of Nondestructive Testing, 2023
Imaging techniques based on ultrasonic Total Focusing Method (TFM1) are more and more applied for industrial applications. Adoption of the technique has been made easier with the publication of the revised ASME V and ISO 23864 and 23865 standards.
Frederic Reverdy, Paul Hillman, Guy Maes
doaj   +3 more sources

Application of Ultrasonic Array Method for the Inspection of TC18 Addictive Manufacturing Titanium Alloy

open access: yesSensors, 2019
Ultrasonic arrays have been investigated for inspecting the quality of special materials. Unfortunately, non-destructive testing and evaluation (NDT&E) of internal defects in additive manufacturing (AM) materials are difficult due to the anisotropy ...
Wentao Li, Zhenggan Zhou, Yang Li
doaj   +1 more source

Plane Wave Imaging through Interfaces

open access: yesSensors, 2021
Plane Wave Imaging (PWI) has been recently proposed for fast ultrasound inspections in the Non-Destructive-Testing (NDT) field. By using a single (or a reduced number) of plane wave emissions and parallel beamforming in reception, frame rates of hundreds
Guillermo Cosarinsky   +2 more
doaj   +1 more source