Influence of Voltage Variation on the Measurement of Total Harmonic Distortion (THD) by AMI Smart Electricity Meters

2021 13th International Conference on Measurement, 2021
Power quality parameters specified in standards IEC 61000–4–30 and EN 50160 are used to power quality evaluation in the power grid. These parameters are, among others higher harmonics and the Total Harmonic Distortion (THD). Measurement and recording of power quality parameters is carried out mainly by power quality analyzers.
openaire   +1 more source

Single phase transformerless semi-Z-source inverter with reduced total harmonic distortion (THD) and DC current injection

2013 IEEE ECCE Asia Downunder, 2013
A single phase transformerless semi-Z-source inverter topology is presented in this paper in order to incorporate distributed photovoltaic generators to the grid with reduced total harmonic distortion (THD) and DC current injection. These proposed inverter topologies are capable of achieving the sinusoidal output voltage by using only two active ...
Tofael Ahmed   +2 more
openaire   +1 more source

RETRACTED: Nonlinear Transformational Optimization (NTO) technique based Total Harmonics Distortion (THD) reduction of line to line voltage for multi-level inverters

Microprocessors and Microsystems, 2020
Abstract Multilevel inverter, switching points at the essential frequency are gained by measuring the total harmonics distortion (THD) in line – line voltage. In this work, an advancement procedure is proposed to register switching angles at basic frequency switching plan by implementing Nonlinear Transformational Optimization (NTO) technique, a like
R. Gunasekaran, C. Karthikeyan
openaire   +1 more source

A Multilevel PV Inverter Control With Minimal Total Harmonic Distortion (THD)

In this article, we have improved the control of the multilevel inverter for a photovoltaic system connected to the grid, in order to minimize the total harmonic distortion of current. This topology being considered as a new converter topology applied to photovoltaic systems and has the advantage of very high-energy efficiency, but has the disadvantage
Lamreoua Abdelhak   +4 more
openaire   +1 more source

Performance analysis of a Nonlinear system with reduced Total Harmonic Distortion (THD) based Hysteresis Current Controller (HCC) using 3 phase DC/AC

2020 International Conference on Computational Intelligence for Smart Power System and Sustainable Energy (CISPSSE), 2020
A nonlinear system determines the quality of power under closed and open control. An issue with power is overcome by a three-phase DC/AC embedded DC/DC ZETA converter with proposed Hysteresis Current Controller (HCC). In this proposed system, personal computers are operated in order to record harmonic generation.
D. Christy Priscilla   +4 more
openaire   +1 more source

Impact of Grid Connected Photovoltaic System on Total Harmonics Distortion (THD) of Low Voltage Distribution Network: A Case Study

2018 Twentieth International Middle East Power Systems Conference (MEPCON), 2018
Integrating renewable energy resources especially photovoltaic systems with microgrids has become an unavoidable choice for most countries and in Egypt the government has this ambition to reach a percentage of 20% of the total national electricity generation from solar energy. Which in turn bring some challenge to the electrical utility operator.
Walaa Ibrahim Gabr   +1 more
openaire   +1 more source

Control and reduction of terminal voltage total harmonic distortion (THD) in a hybrid series active and parallel passive filter system

Proceedings of IEEE Power Electronics Specialist Conference - PESC '93, 2002
A simple and cost-effective solution to reduce the passive filter terminal voltage total harmonic distortion (THD) is outlined. A modified synchronous reference frame (SRF) based controller for the series active filter allows injection of a controlled percentage of the higher harmonic load currents into the supply, in compliance with the IEEE 519 ...
S. Bhattacharya   +2 more
openaire   +1 more source

Design and Implementation of SVPWM Inverter to Reduce Total Harmonic Distortion (THD) on Three Phase Induction Motor Speed Regulation Using Constant V/F

2020 3rd International Seminar on Research of Information Technology and Intelligent Systems (ISRITI), 2020
The electric motor has replaced motor fuel as the main mover of the equipment. One of them is the use of a three-phase induction motor in the industrial sector. Equipment in an industry requires many speed controllers in operation. The induction motor speed can be changed by changing the number of poles, changing the stator voltage, and changing the ...
Arif Sudaryanto   +6 more
openaire   +1 more source

ANALISIS TOTAL HARMONIC DISTORTION ( THD % ) ARUS SECARA TEKNIS PADA GARDU DISTRIBUSI POLITEKNIK NEGERI MALANG

2018
With the standard IEEE 519-1992 Refers harmonics can be identified by comparing the measurement results with those standards so it can be known whether a certain point (point of common coupling) are harmonics. Where the percentage of allowable voltage below 69 kV attached to harmonic voltage is 5% while for Total Harmonic Distortion (THD%)current is 15%
openaire   +1 more source

Classification Based Method Using Fast Fourier Transform (FFT) and Total Harmonic Distortion (THD) Dedicated to Proton Exchange Membrane Fuel Cell (PEMFC) Diagnosis

2017 IEEE Vehicle Power and Propulsion Conference (VPPC), 2017
In this paper, we present an approach for Polymer Electrolyte Membrane Fuel Cell (PEMFC), drying out and flooding diagnosis. The present approach is signal-processing-based pattern recognition. The voltage signal is processed by a Fast Fourier Transform, in order to carry out a frequency analysis and to calculate the Total Harmonic Distortion (THD ...
A. H. Detti   +3 more
openaire   +1 more source