Results 1 to 10 of about 21,965 (267)
Smart Touch Voltage Limitation
In modern railway electric infrastructure design there are two major concerns that should be considered as touch voltage and stray current. The first problem is touch and step voltage which endangers human safety even to deathly situations.
Mahmut Turhan
doaj +4 more sources
On Minimisation of Earthing System Touch Voltages [PDF]
Finding cost efficient earthing system design with acceptable level of safety might be quite tedious work. Thus, many earthing system engineers try to find the most suitable design either by employing only their best experience or taking advantage of ...
Vaclav Vycital +3 more
doaj +3 more sources
Determination of the scope of the experimental-calculation method for measuring the touch voltage
The work is devoted to the improvement of methods for determining the normalized parameters of the grounding system (GS) of operating power stations and substations.
D. G. Koliushko +2 more
doaj +1 more source
Design of AM Self-Capacitive Transparent Touch Panel Based on a-IGZO Thin-Film Transistors
In this work, we propose a novel active-matrix self-capacitance touch panel circuit. Each touch pixel contains only one thin film transistor. The principle of the touch event detection is to detect the voltage change, which is caused by the change of ...
Kejun Wu +6 more
doaj +1 more source
Design, Modeling, and Analysis of IEEE Std 80 Earth Grid Design Refinement Methods Using ETAP
The design of a compliant, safe, and reliable substation earth grid is not a straightforward process; in most cases, it requires some additional measures to be taken due to various constraints that differ from environment to environment, such as soil ...
Vuyani Michael Nicholas Dladla +2 more
doaj +1 more source
Reduction of the step voltages of MV/LV substation grounding system based on shaping electric field [PDF]
The article presents the analysis results of the effectiveness limitation of the step voltage by forming an electric field on the ground surface. For shaping the electric field, a method consisting of screens placed around the point of the earth current ...
Roman Sikora, Przemysław Markiewicz
doaj +1 more source
Piezoelectric force touch panels receive increased attentions in recent years. However, user-induced nonstable force-voltage responsivity limits their successful use in interactive displays.
Anbiao Huang +5 more
doaj +1 more source
Discussion on the Safe Distance Between HVDC Electrode and Pipeline
The safe distance is an important reference for the mutual avoidance and interference reduction between the pipelines and HVDC electrodes in the planning stage.
Yongcong Wu, Hansheng Cai
doaj +1 more source
Effect of Soil Resistivity Measurement on the Safe Design of Grounding Systems
A prerequisite for the proper and safe designing of a grounding system is the full knowledge of the ground structure in the terrain of installation.
Vasilios P. Androvitsaneas +3 more
doaj +1 more source
A novel approach to touch voltage risk assessment for gas pipelines in shared transmission corridors
Touch voltages are more likely to appear on long‐distance pipelines that lie in shared corridors with transmission lines. The touch voltage level varies with soil resistivity and can become hazardous while maintenance is being undertaken, necessitating ...
Keith Man‐Kei Chan +2 more
doaj +1 more source