Results 111 to 120 of about 67,948 (282)

Comparison of the Clinical Use of Macintosh and Miller Laryngoscopes for Orotracheal Intubation by Second-Month Nurse Students in Anesthesiology

open access: yesAnesthesiology Research and Practice, 2010
Aim. The aim of this study is to compare the clinical feasibility of Macintosh and Miller laryngoscopes for tracheal intubation in non-experienced users in anesthetized patients. Patients and Methods. 119 patients were randomized into the Macintosh group
Somchai Amornyotin   +5 more
doaj   +1 more source

Retrospective Analysis of Survival and Adverse Effects Associated With Stereotactic Body Radiation Therapy in 12 Dogs With Hepatocellular Carcinoma

open access: yesVeterinary and Comparative Oncology, EarlyView.
ABSTRACT This retrospective analysis evaluated 12 dogs with hepatocellular carcinoma (HCC) who received stereotactic body radiation therapy (SBRT). Dogs received between 6 and 25 Grey (Gy) per fraction for 1–5 fractions for a total dose of 13–30 Gy. Eleven patients (92%) experienced acute adverse effects (AE), with the majority being VRTOG grade 2–3 ...
Victoria Lee Newberry   +3 more
wiley   +1 more source

Retrospective Study on Liberation in Dogs Undergoing Mechanical Ventilation for Longer Than 24 h

open access: yesJournal of Veterinary Emergency and Critical Care, EarlyView.
ABSTRACT Objective To describe liberation in a population of dogs undergoing ≥24 h of mechanical ventilation (MV) and to assess for differences between successful and unsuccessful liberation attempts as well as adherence to criteria for veterinary and human readiness to discontinue MV. Design Retrospective study.
Abigail E. McNally   +2 more
wiley   +1 more source

Randomized clinical trial of the i-gel™ and Magill tracheal tube or single-use ILMA™ and ILMA™ tracheal tube for blind intubation in anaesthetized patients with a predicted difficult airway [PDF]

open access: yes, 2017
Background The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available.
Graf, T.   +5 more
core  

Preclinical Quantitative In Vivo MRI Assessment of Exogenous Surfactant Pulmonary Distribution After Clinically Relevant Intratracheal Delivery

open access: yesNMR in Biomedicine, Volume 39, Issue 6, June 2026.
Quantitative in vivo contrast‐enhanced UTE MRI enables sensitive and precise mapping of pulmonary surfactant distribution, revealing peripheral localization and homogeneous distal penetration under physiological conditions. Comparison with ex vivo models highlights the role of physiological processes in surfactant retention.
Oumaima Marfouk   +9 more
wiley   +1 more source

The Application of Airtraq (fibreoptic intubation device) to Otolaryngology [PDF]

open access: yes, 2011
The anaesthetic laryngoscope Airtraq is designed for the difficult airway. This disposable laryngoscope requires minimal cervical manipulation and unlike other common anaesthetic larynmgoscopes contains a channel for the guidance of an endotracheal tube.
Mendis, D, Oates, J
core   +1 more source

Cervical Resection of a Suprapericardial Retrosternal Goiter Without Thoracotomy: A Case Report

open access: yesClinical Case Reports, Volume 14, Issue 5, May 2026.
ABSTRACT A cervical approach combined with thoracoscopic assistance and preoperative tracheal stenting offers a safe and minimally invasive alternative to sternotomy for managing retrosternal goiters extending to the pericardium with severe airway compression.
Yuanjing Lv, Cheng Xiang
wiley   +1 more source

Stimulation induced variability of pulse plethysmography does not discriminate responsiveness to intubation [PDF]

open access: yes, 2017
Background. Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG ...
Gils, M.   +5 more
core  

A Case of a Child With Persistent Cough Caused by Dental Aspiration

open access: yesClinical Case Reports, Volume 14, Issue 5, May 2026.
ABSTRACT Dental aspiration is usually reported in children with underlying disorders, such as neuromuscular disorders, and is rare in healthy children. Although foreign body aspiration typically causes a persistent cough in infants, herein we report a healthy adolescent whose persistent cough was due to dental aspiration.
Hiroshi Imai   +6 more
wiley   +1 more source

Anesthetic Management of Acute Right Tension Pneumothorax in a Child With Left Main Bronchial Foreign Body: A Case Report

open access: yesClinical Case Reports, Volume 14, Issue 5, May 2026.
ABSTRACT In children with complete unilateral main bronchial obstruction from foreign body aspiration, positive pressure ventilation may overdistend the contralateral ventilated lung, leading to barotrauma and tension pneumothorax. Sudden hypoxemia and hypotension should prompt rapid clinical assessment, including lung ultrasound, and immediate ...
Kun Yue, Xuewu Ji, Yingying Sun, Yin Xia
wiley   +1 more source