Results 1 to 10 of about 413 (183)
Quality Parameters of Electricity Supplied to Electric Railways
The paper analyses the most relevant unfavourable impact of AC electric traction on the quality parameters of supplied electric energy. These are: power factor of fundamental harmonic and power factor, voltage a current harmonic components, unbalance and
Juraj Altus +4 more
doaj +1 more source
Reversible Substation in DC Traction
In order to improve the green foot prints and also reduce the operational costs, it is currently standard practice to fit the Rolling stock of Metros railway units with regenerative dynamic braking systems. Thus, energy generated by a braking train can be reused by other accelerating trains.
openaire +1 more source
Research on traction load forecasting of electrified railway
In order to ensure the power quality of traction power supply system and reduce the costs for purchasing electricity by traction substation, a probabilistic forecasting model of traction load based on sparse Gaussian process (SGP) is proposed.
LIU Fu, LIAO Qishu
doaj
In railway traction, the definition of “electromagnetic field” is functionally connected to the concept of the reactive power consumed by the electric rolling stock, and characterized by the running and standing electromagnetic waves in the space of the ...
Mykola Kostin +3 more
doaj +1 more source
The traction return system of high-speed railways comprises multiple conductors, including rails, protective wires (PW), through ground wires, and substation ground grids, making it difficult to accurately calculate the impedance parameters of each ...
Zicheng WANG
doaj +1 more source
The traction power supply system will have high amplitude transient overvoltage after lightning stroke, which will affect the stable operation of railway transportation system.
XIE Xuefang
doaj
Research on the Reliability of Metro Traction Substation Main Wiring
In order to accurately and efficiently evaluate the reliability of a subway traction substation and improve the traditional fault tree reliability analysis method, it presented a Bayesian network analysis method based on fault tree, which can greatly ...
XU Hao
doaj
RECTIFIER TRANSFORMERS IN ELECTRIC TRACTION SUBSTATIONS ‐ DIFFERENT DESIGNS
Electric traction in Poland is supplied with dc voltage which is obtained from the power grid via traction substations equipped with transformers and rectifiers. The paper gives the results of the investigation of different designs of these transformer‐rectfier sets ‐ namely, 12‐ and 24‐pulse systems.
openaire +4 more sources
THE MINIMALIZATION OF FILTER EQUIPMENT FOR TRACTION SUBSTATIONS USING BOOSTER CONVERTER
The structure of traction substation 3,2 kV DC power source is considered. It is shown that the output filter choke of traction substation with voltage added converter may be excluded. A dynamic model of voltage added converter is developed, its features,
Yu. P. Goncharov +4 more
doaj
Simulation Studies of the Underground DC Traction Substation with and without Energy Storage Device
This paper presents the results of the underground DC traction substation simulation studies for two versions: the substation equipped with the ESD (Energy Storage Device) and without the ESD.
Elzbieta Szychta +4 more
doaj +1 more source