Design of Transformer Oil Temperature Intelligent Monitoring and Alarm System Based on PLC
According to the requirements of the transformer oil product management system, the overall plan is designed, PLC is used as the next machine, and the distributed I/O system is built, based on the system software design transformer electrical schematic ...
Kun Zhang
doaj +1 more source
Analysis of real operating condition revealed that HVDC transformers experience combined effect of DC biased AC electric field. The dynamics of pressboard particle in contaminated transformer oil under the influence of DC, AC and DC biased AC electric ...
Mahmud, S. +4 more
core +1 more source
An investigation into the dynamics of partial discharge propagation in mineral oil based nanofluids [PDF]
Recent studies present a model which assumes that conductive nanoparticles can reduce the speed of the positive streamer propagation in mineral oil due to electron trapping at the particle surface. Time resolved partial discharge measurements can be used
Peter H.F. Morshuis +7 more
core +1 more source
A method of transformer top oil temperature forecasting based on similar day and similar hour
As the transformer top oil temperature is affected by many factors such as weather conditions and tidal current loads,it is difficult to improve the forecasting accuracy. To solve this problem,a method of transformer top oil temperature forecasting based
TAN Fenglei +4 more
doaj +1 more source
Biomolecular condensates formed by fused in sarcoma (FUS) are dissolved by high ATP concentrations yet persist in cells. Using a reconstituted system, we demonstrate that valosin‐containing protein (VCP), an AAA+ ATPase, counteracts ATP‐driven dissolution of FUS condensates through its D2 ATPase activity.
Hitomi Kimura +2 more
wiley +1 more source
An isoform of 14‐3‐3 protein regulates transbilayer lipid movement at the plasma membrane
Loss of 14‐3‐3ζ in CHO cells confers resistance to exogenous phosphatidylserine (PS) and impairs endocytosis‐independent inward flip‐flop of fluorescent PS at the plasma membrane. RNAi‐mediated knockdown reproduces this defect, while no additive effect is seen in ATP11C‐deficient cells.
Akiko Yamaji‐Hasegawa +3 more
wiley +1 more source
Analisis Kualitas Minyak Trafo Menggunakan Data Dissolved Gas Analysis dan Water Content
Transformer is a vital equipment in the power system. If the transformer is damage, can cause the electrical distribution to the consumer will be disrupted. Therefore, it needs special maintenance the performance of the transformer to avoid damage.
Abdul Syakur, Fanny Rizka Savitri
doaj +1 more source
We present robust protocols for the preparation of supported lipid bilayers (SLBs) incorporating either Salmonella smooth LPS or outer membrane vesicles (OMVs). We use a combination of quartz crystal microbalance with dissipation (QCM‐D) and fluorescence microscopy to both characterize the SLBs of various compositions and to probe their interactions ...
Hudson P. Pace +6 more
wiley +1 more source
Performance evaluation of transformer oil using uv-visible spectrophotometer
To ensure reliable operation of Power transformer, condition monitoring of transformer becomes obligatory. In this paper, condition assessment of transformer oil under various working conditions is performed using UV-visible spectrophotometer.
Radha Karthik +2 more
doaj +1 more source
Peripheral lysosomes recruit PLEKHG3 to focal adhesions and restrain protrusion dynamics
Proximity‐dependent labeling at the LAMTOR complex revealed the Rho GEF PLEKHG3 as a lysosome‐proximal protein directing the study toward the influence of lysosome positioning on actin dynamics and cell motility. We show that PLEKHG3 colocalizes with lysosomes at focal adhesion sites and observe that forced peripheral dispersion of lysosomes hinders ...