Results 51 to 60 of about 1,377,829 (293)

Importin 7 mediates the nuclear import of HIV‐1 integrase via a specific interacting interface

open access: yesFEBS Open Bio, EarlyView.
HIV‐1 integrase enables viral DNA integration into the host genome. By binding to the core domain of the host protein Importin 7 via its C‐terminal domain, the integrase is transported across the nuclear membrane into the nucleus, where integration of the viral genome into host DNA takes place. This translocation is a critical step for subsequent viral
Juana Bana   +5 more
wiley   +1 more source

The influence of magnetite nano particles on the behavior of insulating oils for pulse power applications [PDF]

open access: yes, 2011
The effects of the addition of magnetite nanoparticles on the breakdown strength of three insulating liquids have been examined. The liquids considered are: a mineral transformer oil; a synthetic ester liquid, Midel 7131, and a specialist high ...
Given, M   +6 more
core   +4 more sources

Improving the thermal performance of electrical transformers using hybrid mixture of (transformer oil, nanoparticles, and PCM)

open access: yesAl-Qadisiyah Journal for Engineering Science, 2020
In this paper, an experimental electrical distribution transformer was studied and a new technique was proposed to improve the performance of a new mixed cooling consisting of pure transformer oil, paraffin wax and nanoparticles.
Mushtaq I. Hasan   +2 more
doaj   +1 more source

Ionomycin suppresses cancer cell growth by disrupting mitochondrial transcription

open access: yesFEBS Open Bio, EarlyView.
In this study, we identify a new function for the selective Ca2+ ionophore, ionomycin, as an inhibitor of mitochondrial transcription. Both total and nascent RNA analyses revealed that ionomycin treatment reduces the transcription of mitochondrial genes.
Lishen Wang   +10 more
wiley   +1 more source

Simulation of dielectric frequency response of transformer insulation system

open access: yes, 2013
Frequency domain spectroscopy has been widely used to monitor the condition of insulation system in power transformers. For a core type of transformer, a simplified XY model of a duct has been developed which allows one to examine the contribution from ...
Yu, Guo, Chen, George
core   +1 more source

Effects of Add‐On Icosapent Ethyl With Standard Treatment on Functional Outcomes and Inflammatory Biomarkers in Acute Ischemic Stroke: A Blinded Randomized Controlled Trial

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background Ischemic stroke, a major cause of mortality and long‐term disability, results from the abrupt cessation of cerebral blood flow due to vascular occlusion or rupture. Icosapent Ethyl (EPA‐EE), approved for hypertriglyceridemia, has anti‐inflammatory and antithrombotic properties that may lessen ischemic damage.
Mitra Mahmoudi Meymand   +5 more
wiley   +1 more source

Electrical insulating liquid: A review [PDF]

open access: yesJournal of Advanced Dielectrics, 2017
Insulating liquid plays an important role for the life span of the transformer. Petroleum-based mineral oil has become dominant insulating liquid of transformer for more than a century for its excellent dielectric and cooling properties.
Deba Kumar Mahanta, Shakuntala Laskar
doaj   +1 more source

OntOMat: Toward Ontology‐Based Product and Process Design Engineering and Optimization Solutions Fueling Circular Value Chains

open access: yesAdvanced Engineering Materials, EarlyView.
The OntOMat ontology establishes a structured framework for polymer matrix fiber reinforced composite materials, integrating manufacturing processes, characterization methods, and multiscale design through the VDI/VDE 3682 formalized process description standard.
Nicolas Christ   +19 more
wiley   +1 more source

Investigations of thermal degradation and spectral response of transformer oil - doi: 10.4025/actascitechnol.v35i2.15190

open access: yesActa Scientiarum: Technology, 2013
In order to maintain continuous power supply in the electrical system, condition monitoring of the sensitivity equipments in power system is very essential. Among those equipment in which more concentration required is Power transformer. To determine the
Karthik Radha   +1 more
doaj   +1 more source

Integration of OpenCV‐Based Microscopic Adhesive Volume Measurement Into a Pyiron Workflow for Automated Data Analysis

open access: yesAdvanced Engineering Materials, EarlyView.
Residual adhesive after electrode loading in adhesive‐assisted resistance spot welding is quantified through a traceable experimental‐to‐digital workflow. Chromatic confocal topography provides calibrated surface‐height data, while OpenCV detects the electrode imprint and integrates adhesive height into comparable volume metrics.
Sung‐Min Wi, Jiangdong Zhao
wiley   +1 more source

Home - About - Disclaimer - Privacy