Results 61 to 70 of about 9,842,775 (252)

Faulty Feeder Detection Method Based on VMD–FFT and Pearson Correlation Coefficient of Non-Power Frequency Component in Resonant Grounded Systems

open access: yesEnergies, 2020
Through analyzing the transient components and transient characteristics in transient zero-sequence current (TZSC), a novel fault feeder detection method based on the transient correlation of non-power frequency components (NPFCs) for the resonant ...
Kewen Wei   +4 more
doaj   +1 more source

Vector Modulation-Based Model Predictive Current Control with Filter Resonance Suppression and Zero-Current Switching Sequence for Two-Stage Matrix Converter

open access: yesEnergies, 2021
This paper proposes a novel model predictive current control scheme for two-stage matrix converter. The switching frequency is kept constant by fixing the switching instant. The control strategy achieves to control source reactive power in the input side
Zhengfei Di, Demin Xu, Kehan Zhang
doaj   +1 more source

Wavelet Based Induction Motor Fault Diagnosis Using Zero Sequence Current

open access: yes, 2017
Induction motor stator fault is diagnosed by applying Discrete Wavelet transform on zero sequence components. The single phasing stator fault is created and diagnosed in the induction motor model developed in stationary reference frame, under varying ...
W Abitha Memala, V Rajini
core   +1 more source

Chronobiology of Cancer: How Aging Fuels Oncogenesis at the Molecular Level

open access: yesAging and Cancer, EarlyView.
This graphical abstract illustrates the key biological pathways linking aging with cancer development and progression. In the upper left, cumulative exposure to ultraviolet radiation, toxins, and reactive oxygen species (ROS) causes DNA damage and genomic instability, whereas age‐related decline in repair mechanisms, such as ATM/ATR, BER, and NER ...
Anu Singh, Aroonima Misra, Sufian Zaheer
wiley   +1 more source

Line Selection Device of Small Current Single-phase Grounding Fault Based on Integrative Line Selection Strategy

open access: yesGong-kuang zidonghua, 2012
For the deficiency of single line selection principle, the paper proposed integrative line selection strategy, namely zero sequence admittance method, zero sequence susceptance increment method and zero sequence conductance method based on steady-state ...
LI Hui, TANG Yi, SUN Chang-qing
doaj  

White Matter Hyperintensity Burden and Short‐Interval Change Associated With Sleep Apnoea in the UK Biobank

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background and Purpose White matter hyperintensities (WMH) are a core neuroimaging marker of cerebral small vessel disease (CSVD). Sleep apnoea (SA) is a recognized vascular risk factor, but its associations with regional WMH burden, short‐interval WMH change and cognitive performance in population‐based cohorts remain incompletely defined. We
Peng Cheng   +4 more
wiley   +1 more source

Fault line selection method for distribution network based on measurement of characteristic atom

open access: yesGong-kuang zidonghua, 2017
For problems that fault feature extraction was not enough and fault line selection criterion needs samples with long training time in existing fault line selection methods for distribution network, a fault line selection method for distribution network ...
ZHAO Liang, ZHOU Nuoying, WANG Xiaowei
doaj   +1 more source

Sertraline Treatment Can Mimic Niemann‐Pick Type C Biomarker Profile: A Diagnostic Pitfall

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background Oxysterols (cholestane‐3β,5α,6β‐triol and 7‐ketocholesterol) and N‐palmitoyl‐O‐phosphocholineserine (PPCS) are sensitive biomarkers for Niemann‐Pick disease type C (NPC) screening. However, false‐positive results occur, with a biomarker profile suggestive of NPC despite the absence of pathogenic variants in genes involved in NPC or ...
Maria Makrygianni   +19 more
wiley   +1 more source

Calculation of Zero Sequence Inductance of a Three-Phase Reactor

open access: yes, 2017
Zero sequence impedance is an essential parameter for the analysis of unbalanced faults and protection in the electrical power system. An inductance per phase is used between grid and AC/DC voltage source converter in order to control the real and ...
Selici, Dilara, AKPINAR, EYUP
core   +1 more source

Neurovascular Contacts in the Pathophysiology of Neuralgic Amyotrophy: An Observational Study

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Neuralgic amyotrophy (NA) is a prevalent, monophasic, multifocal immune‐mediated neuropathy. A distinctive characteristic of the disease is the occurrence of nerve or fascicle constrictions and torsions (NA‐associated focal nerve lesions, NAFL). The pathophysiology underlying this phenomenon remains to be fully elucidated.
Johannes Fabian Holle   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy