Results 301 to 310 of about 63,195 (336)
Some of the next articles are maybe not open access.

Vibro-Acoustography: Speckle Free Ultrasonic C-Scan

2002
In an in vitro experiment the acoustic emission characteristics of broken and intact struts on BSCC valves exhibited different frequency responses and different vibro-acoustography images. The images indicated that the vibration modes of the object could be deduced in addition to the structural integrity of the object.
James F. Greenleaf   +2 more
openaire   +1 more source

Experimental ESD method for restoration of blurry image in ultrasonic C-Scan

2010 International Conference on Mechanic Automation and Control Engineering, 2010
A 2-D Deconvolution method for the improvement of ultrasonic defocused C-scan images is presented by using experimental Edge Spread Distribution (ESD) of transducer. In the paper, experiments corresponding different imaging depth were implemented to establish a relation of the ESD and blurry C-scan images.
null Tao Kong   +2 more
openaire   +1 more source

A clustering-based damage segmentation for ultrasonic C-Scans of CFRP plates

2015 IEEE International Ultrasonics Symposium (IUS), 2015
Despite their desirable mechanical properties, damage propagation in carbon fiber-reinforced polymers (CFRP) due to manufacturing flaws and continued use may particularly be hard to assess. In this work, damage maps are generated to identify the health state of a CFRP plate from ultrasonic signals obtained under C-Scan mode.
Antonio Rodriguez-Hidalgo   +4 more
openaire   +1 more source

Neural network-based ultrasonic C-scan imaging of austenitic structures

The Journal of the Acoustical Society of America, 1999
Results of new studies of C-scan imaging on austenitic welds, used in conjunction with artificial neural network techniques, are reported. The C-scan technique provides high-resolution images of subsurface zones which are inaccessible by conventional A-scans.
Petre Petculescu, Dorin Ciobanu
openaire   +1 more source

Ultrasonic C-scan Image Restoration Using Radial Basis Function Network

2004
A method for restoration of ultrasonic C-scan images is presented by using a radial basis function network. The method attempts to reproduce the mapping between the degraded C-scan image and the high quality one by training a RBF network. The inputs for training are the sub-images divided from C-scan image of flat-bottom hole of size 3mm and the output
Zongjie Cao   +3 more
openaire   +1 more source

"Synthetic axial acquisition" full resolution C-Scan ultrasonic imaging

IEEE Ultrasonics Symposium, 2005., 2006
This work relates to efficient and low cost acquisition of beamformer data for C-Scan imaging. In our previously described Directly Sampled In-phase and Quadrature (DSIQ) approach (1), as few as one complex sample per array element is used. In the 'Synthetic Axial Acquisition' (SAA) approach presented here, we take advantage of the fact that we use an ...
Y. Li   +3 more
openaire   +1 more source

Imaging of the Ultrasonic Velocity and Reflection Properties of Objects by a C-Scan Method

1984
A method and imaging system for the measurement of the ultrasonic velocity and reflection properties of objects are described. Some preliminary images of test cylinders and brain specimen are shown and the various imaging difficulties are discussed. The measured velocity values are in agreement with those found in the literature and in the images a ...
K. Tervola   +3 more
openaire   +1 more source

Fiber orientation study using ultrasonic C-scan of ply interfaces

AIP Conference Proceedings, 2002
A new method for direct mapping of ply orientations in composite laminates is presented. The method employs normal incidence ultrasound to scan ply interfaces and produce C-scan images that contain primarily the fiber orientation information of local plies.
openaire   +1 more source

Microstructure Characterization of Cancellous Bone Based on Ultrasonic C-Scan Imaging

2017
Ultrasonic backscatter signals can reflect the microstructural information of cancellous bone. The goal of this study is to characterize the microstructure of cancellous bone in the mesoscale and estimate trabecular thickness (Tb.Th), trabecular bone separation (Tb.Sp), bone volume fraction (BV/TV) and structure model index (SMI) based on ultrasonic C ...
Ying Li   +3 more
openaire   +1 more source

Improving Ultrasonic C-Scan Resolution Using the Hilbert-Huang Transform

AIP Conference Proceedings, 2005
The Hilbert Huang Transform (HHT) is applied to ultrasonic mapping of simulated defects in an aluminum plate. C‐Scanning tests are conducted using pulse‐echo ultrasound on a water‐immersed aluminum plate containing a matrix of 16 unevenly‐spaced flat‐bottomed holes.
openaire   +1 more source

Home - About - Disclaimer - Privacy