Results 91 to 100 of about 52,181 (311)

A Novel Model of Ultrasonic Fatigue Test in Pure Bending. [PDF]

open access: yesMaterials (Basel), 2022
Yang D   +10 more
europepmc   +1 more source

Experimental and analytical study of fatigue damage in notched graphite/epoxy laminates [PDF]

open access: yes
Both tension and compression fatigue behaviors were investigated in four notched graphite/epoxy laminates. After fatigue loading, specimens were examined for damage type and location using visual inspection, light microscopy, scanning electron microscopy,
Whitcomb, J. D.
core   +1 more source

The effects of material combination and surface roughness in lubricated silicon nitride/steel rolling contact fatigue [PDF]

open access: yes, 2003
Four kinds of commercially finished 12.7 min HIPed silicon nitride bearing balls with surface roughness values R-a ranging from 0.002 to 0.016 mum were tested using a four-ball rolling configuration.
Ahmed, R, Hadfield, M, Kang, J
core   +1 more source

Microstructured Electrode‐Piezopolymer Interface for Ultrasound Transducers With Enhanced Flexibility and Acoustic Performance

open access: yesAdvanced Materials Technologies, EarlyView.
Flexible piezopolymer ultrasound transducers are engineered by tailoring the electrode–piezopolymer interface using metallic, flake‐based, and porous graphene electrodes. Laser‐induced graphene's porous structure enables polymer infiltration, strengthening interfacial coupling and enhancing piezoelectric response and acoustic output.
Spencer Hagen   +3 more
wiley   +1 more source

Ultrasonic fatigue analysis of 3D-printed carbon fiber reinforced plastic. [PDF]

open access: yesHeliyon, 2022
Jung CH, Kang Y, Song H, Lee MG, Jeon Y.
europepmc   +1 more source

The detection of tightly closed flaws by nondestructive testing (NDT) methods [PDF]

open access: yes
Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations.
Mullen, S. J.   +3 more
core   +1 more source

Instantaneous baseline damage localisation using sensor mapping [PDF]

open access: yes, 2016
In this paper an instantaneously recorded baseline method is proposed using piezoelectric transducers for damage localisation under varying temperature.
Aliabadi, MH   +2 more
core   +1 more source

Graphene‐Interfaced Stretchable Sweat Patch for Multiplexed Electrochemical Monitoring of IL‐6, Glucose, and Calcium Ions

open access: yesAdvanced Materials Technologies, EarlyView.
Flexible sweat sensor patch integrating graphene‑interfaced gold microelectrodes functionalized with bio‑receptors and ion‑selective membrane, coupled with a capillary‑driven microfluidic layer and portable potentiostat electronics for multiplexed monitoring of inflammatory, metabolic, and electrolyte biomarkers in microliter sweat volumes.
Roomia Memon   +4 more
wiley   +1 more source

Ultrasonic fatigue tests on maraging 300 steel: Under solution annealed, after aging heat treatment and under pre-corrosion attack

open access: yesForces in Mechanics
Ultrasonic fatigue tests were carried out under continuous cycling on the maraging 300 steel for the following conditions: (A) solution annealed (as received from supplier), (B) after aging heat treatment of 490 °C for 6 h, (C) after pre-corrosion attack,
Julio A. Ruiz Vilchez   +2 more
doaj   +1 more source

A Novel Ultrasonic Fatigue Test and Application in Bending Fatigue of TC4 Titanium Alloy. [PDF]

open access: yesMaterials (Basel), 2022
Tang S   +9 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy