Unbalanced Current in Split Brushes
Main traction motors MT 200 for the New Tokaido Line, which are used at high speed and high current density in pulslating or direct current, are carefully designed in order to keep good commutation and the brushes used are split ones made from soot.
Kokubu, K., Kumagai, M.
openaire +3 more sources
To handle the unbalanced vibration caused by uneven rotor mass distribution in a bearingless induction motor (BIM), a control strategy that integrates unbalanced feed-forward compensation and current compensation is presented.
Huimin Zhu +4 more
doaj +1 more source
This paper proposes an effective fault management scheme for medium‐voltage direct current (MVDC) networks, which includes a virtual‐impedance‐based fault current limiter (VI‐FCL) on the DC side and a positive‐negative‐sequence (PNS) control scheme on ...
Dongsen Sun +3 more
doaj +1 more source
Comprehensive Power Losses Model for Electronic Power Transformer
The electronic power transformer (EPT) has higher power losses than the conventional transformer. However, the EPT can correct the power factor, compensate the unbalanced current, and reduce the line power losses in the distribution network.
Quanyou Yue +6 more
doaj +1 more source
Unbalanced issues and power quality problems can be handled using shunt active power filters (APFs). Under weak grid conditions and unbalanced grid impedance, the unbalanced three-phase load leads to unbalanced grid currents and point-of-common-coupling ...
Mohammad Alathamneh +2 more
doaj +1 more source
Complex electromagnetic field in converter station poses a serious interference to the field test of unbalanced current of high voltage capacitor bank, and the unbalanced current is too small to be accurately measured directly during the test. This paper
Peng WU, Yuan ZHANG, Lei SHI
doaj +1 more source
Improved control of virtual synchronous generator under unbalance of grid voltage
Asymmetric faults in the power grid will lead to unbalanced grid voltage. When the traditional VSG control operates under unbalanced grid voltage, the output current will be unbalanced, resulting in output power oscillation.
Chunxue Wen +3 more
doaj +1 more source
Research on Three-phase Unbalance of Micro-grid Based on Active Disturbance Rejection Control
Under the condition of three-phase unbalanced load in micro-grid, three-phase four-leg inverter can solve the unbalanced three-phase output voltage because of unbalanced load.
Mengran QIAN, Hui LI, Xinxiu LIU
doaj +1 more source
Comprehensive Modeling of Induction Motor Imbalance Condition to Precise Assessment of Steady State Performance Based on Complex Current Unbalance Factor [PDF]
After a comprehensive study of voltage unbalance issue, this paper presents the defects of some unbalance factors and concentrates on the importance of considering the angle of complex voltage unbalance factor (CVUF) in order to unbalanced condition ...
Saeed Maghsoodi +3 more
doaj +1 more source
Unbalanced current-based tariff
The voltage and current unbalances are serious power quality problems with interaction on each other and mainly affecting low-voltage electricity distribution three-phase systems. In a three-phase system, the current unbalance is due to load unbalance, while it is considered as the main cause of voltage unbalance.
Hossein Arghavani, Mitra Peyravi
openaire +1 more source