Measurement Method for Mold Slag Thickness in Continuous Casting Mold Using Millimeter-Wave Radar and Eddy Current Sensors. [PDF]
An Y, Wang Z, Xiao J.
europepmc +1 more source
Linking electrical anomalies in the upper mantle to petrological and geochemical heterogeneities. [PDF]
Yang X, Xu YG, Xia QK.
europepmc +1 more source
Polymers with Upper Critical Solution Temperature in Aqueous Solution [PDF]
AbstractThis review focuses on polymers with upper critical solution temperature (UCST) in water or electrolyte solution and provides a detailed survey of the yet few existing examples. A guide for synthetic chemists for the design of novel UCST polymers is presented and possible handles to tune the phase transition temperature, sharpness of transition,
Jan Seuring, Seema Agarwal
exaly +6 more sources
Related searches:
Upper critical solution temperature polymeric drug carriers
Chemical Engineering Journal, 2022Huatang Zhang, Yong-Guang Jia
exaly +2 more sources
Upper Critical Solution Temperature Polyvalent Scaffolds Aggregate and Exterminate Bacteria
Small, 2022AbstractSpecific recognition and strong affinities of bacteria receptors with the host cell glycoconjugates pave the way to control the bacteria aggregation and kill bacteria. Herein, using aggregation‐induced emission (AIE) molecules decorated upper critical solution temperature (UCST) polyvalent scaffold (PATC‐GlcN), an approach toward visualizing ...
Meng Gao, Yunhua Chen, Liu
exaly +3 more sources
Nonionic Polymer with Flat Upper Critical Solution Temperature Behavior in Water
Biomacromolecules, 2021We rationally designed a monomer that when polymerized formed a well-defined nonionic polymer [poly(2-(methacryloyloxy) ethylureido glycinamide), PMEGA] by reversible addition fragmentation chain transfer with a flat and tunable upper critical solution temperature (UCST) in water.
Md. D. Hossain +4 more
openaire +3 more sources
Flory Temperature and Upper Critical Solution Temperature of Gelatin Solutions
Biomacromolecules, 2005The Flory temperatures (theta) measured by turbidity experiments performed on gelatin solutions were found to be 12 +/- 0.3, 13 +/- 0.3, 14 +/- 0.3, 14.5 +/- 0.3, and 15 +/- 0.3 degrees C for salt concentrations 0.1, 0.075, 0.05, 0.025, and 0 M (NaCl), respectively.
Amarnath, Gupta +2 more
openaire +2 more sources
Upper and Lower Critical Solution Temperatures in Polystyrene Solutions. II
Macromolecules, 1973Abstract Upper and lower critical solution temperatures have been determined for solutions of polyethylene in n-butyl acetate and n-amyl acetate over the molecular weight range of M η = 1·36 × 10 4 to 17·5 × 10 4 . Polyethylene solution in n-butyl acetate displays a smaller miscibility region than that of the polyethylene/n-amyl acetate system,
N. Kuwahara +3 more
openaire +1 more source
Nonionic star polymers with upper critical solution temperature in aqueous solutions
Polymer Chemistry, 2022Novel UCST star poly(2-ureido methacrylates) synthesized via the ARGET ATRP technique showed enhanced trapping abilities of model drug molecules.
Aliaksei Aliakseyeu +2 more
openaire +1 more source
AbstractWater‐soluble and thermoresponsive macrocycles with stable inclusion toward guests are highly valuable to construct stimuli‐responsive supramolecular materials for versatile applications. Here, we develop such macrocycles – ureido‐substituted cyclodextrins (CDs) which exhibit unprecedented upper critical solution temperature (UCST) behavior in ...
Kun Liu, Xiacong Zhang, Jiatao Yan
exaly +3 more sources

