Current interruption in vacuum

1994
The vast majority of power switching devices spend almost all their service life in the closed position, conducting current to a load. Yet the major effort in their design and development is directed to the relatively infrequent occasions when, on command, they interrupt this current, or to the even rarer occasions, when they operate in anger to clear ...
openaire   +1 more source

VACUUM INTERRUPTER CHAMBER

2007
The invention relates to a vacuum interrupter chamber having an insulating ceramic wall, within which contact pieces which move in a vacuum are arranged and are surrounded by a screen between the contact piece and the interrupter chamber wall, according to the preamble of patent claim 1.
ABB TECHNOLOGY AG   +3 more
openaire   +1 more source

Review of vacuum interrupter development carried out in London by Vacuum Interrupters Limited

29th Annual Weekend Meeting History of Electrical Engineering, 2001
Vacuum Interrupters Limited was founded in 1968. This was a joint venture originally between GEC which inherited the work carried out by English Electric and AEI, together with Reyrolle- Parsons, and later including Hawker-Sidderly (Brush). This paper concentrates briefly on some of the innovative technology developed during the period from 1968-92 ...
openaire   +1 more source

Interruption ability of vacuum interrupters subjected to axial magnetic fields

Proceedings of the Institution of Electrical Engineers, 1972
Two vacuum interrupters equipped with 7 cm-diameter electrodes have been power tested with and without the presence of an axial magnetic field during arcing. The field strength was 2×10−5 teslaper arcing ampere, with a negligible field at a current zero.
C.W. Kimblin, R.E. Voshall
openaire   +1 more source

Post arc current of vacuum interrupter after large current interruption

IEEE Transactions on Power Delivery, 1988
Postarc current characteristics of a vacuum interrupter have been examined under a condition of high-current interruption. A measurement technique was developed in which a shunt for measuring postarc current was set in a synthetic test circuit voltage source. Postarc current was measured after a 20-57 kA current interruption.
Y. Hakamata   +4 more
openaire   +1 more source

Fiber-controlled vacuum interrupter module used for fault current interruption

24th ISDEIV 2010, 2010
A novel fiber-controlled vacuum interrupter module (FCVIM) is proposed in this paper, which can be used for controlled interruption of short circuit currents by means of point-on-wave control. In the FCVIM, the permanent magnetic actuator operates at high potential terminal with the vacuum interrupter, the operation commands come from low potential ...
Xiongying Duan   +3 more
openaire   +1 more source

Resistance increase of vacuum interrupters due to high-current interruptions

IEEE Transactions on Dielectrics and Electrical Insulation, 2014
The resistance of vacuum interrupters can be calculated from the geometry and resistivity of current carrying parts and the additional resistance of the contact points between movable and fixed contacts. Since vacuum interrupter contacts are designed as flat contacts facing each other, the resistance is mainly determined by contact force, hardness and ...
E. Dullni   +3 more
openaire   +1 more source

Electrical breakdown in vacuum interrupters

IEEE Transactions on Electrical Insulation, 1993
Aspects of HV breakdown associated with vacuum interrupters are discussed, based on the author's personal experience. In particular, cold cathode arc stability, electrical contact phenomena, and particle effects are considered. >
openaire   +1 more source

Contact Materials for Vacuum Interrupters

IEEE Transactions on Parts, Hybrids, and Packaging, 1974
A comprehensive review of the large number of contact materials that have been proposed for vacuum interrupter applications is presented. These contact materials are classified into four major groupings: 1) pure metals, 2) alloys, 3) mixtures of refractory materials and good conductors, and 4) mixtures of semirefractory materials and good conductors ...
openaire   +1 more source

Interruption property of vacuum interrupter with four different contact materials

2017 4th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST), 2017
Interruption property of vacuum interrupter with four different contact materials were researched by experimental method. The diameter of Wan-type contact and Spiral-type CuCr25 contact was 55mm. The diameter of Spiral-type CuCr35 and CuCr30 was 58mm.
Min Li   +3 more