Mitral Valve Repair in Patients With Class I Obesity: A Propensity-Matched Analysis. [PDF]
Danesh S +11 more
europepmc +1 more source
Architected Load Paths Enable Stiffening and Motion Programming in Soft Pneumatic Actuators
A single MARS template introduces an architected reinforcement strategy for programmable soft pneumatic actuators through internal structural organization and selective beam removal. This monolithic architecture enables deformation reconfiguration from continuous bending to joint‐like articulation and torsional motion, allowing one compliant platform ...
Jie Wang +6 more
wiley +1 more source
Mitral valve annuloplasty for degenerative disease: assessment of four different techniques
mitral valve repair techniques and follow ...
Bortolotti U. +6 more
core
Active Oscillations of Elastic Membranes Arising from the Coupling with a Catalytic Reaction
Coupling an elastic membrane to a catalytic reaction produces active oscillations that self‐sustain for hours: the membrane cyclically inflates and deflates as the reaction spontaneously activates and deactivates, without external power. Energy release is directly embodied in the oscillation dynamics, opening elasto‐chemical strategies for the physical
Alberto Comoretto +5 more
wiley +1 more source
Mitral and tricuspid valve repair in a patient with eosinophilic granulomatosis with polyangiitis. [PDF]
Dąbrowska A +3 more
europepmc +1 more source
Neuronal activation leads to astrocytic transient volume changes, activating transient receptor potential ankyrin 1 (TRPA1) channels, leading to Ca2+ influx. Activation of TRPA1 causes the release of D‐serine through BEST1. Finally, the augmented extracellular levels of D‐serine boost neuronal activity by binding GluN1‐containing NMDARs, leading to CBV
Kayoung Han +11 more
wiley +1 more source
Tricuspid valve repair in infective endocarditis. [PDF]
Meidrops K +4 more
europepmc +1 more source
Experiments on Nonlocal Fluid‐Flow Metamaterials
A nonlocal fluid‐flow metamaterial composed of standard microfluidic tubes and connectors is designed. Hence, the current of the system at one position depends on the gradient of fluid flow at many other positions, leading to unusual alternating backward and forward laminar flows of water.
Ke Wang, Yi Chen, Martin Wegener
wiley +1 more source
Hemodynamic Changes After Transcatheter Valve Repair and Replacement for Tricuspid Regurgitation. [PDF]
Alabdaljabar MS +10 more
europepmc +1 more source
Emergence of Unconventional Magnetic Order in Strain‐Engineered RuO2/TiO2 Superlattices
Epitaxial strain activates unconventional magnetism in rutile RuO2, absent in bulk or relaxed RuO2. Polarized neutron reflectometry with atomic‐layer resolution directly reveals finite magnetization confined to RuO2 layers in fully strained RuO2/TiO2 superlattices on TiO2 (110).
Seung Gyo Jeong +12 more
wiley +1 more source

