Results 231 to 240 of about 724,235 (283)
Some of the next articles are maybe not open access.
Energy conservation in vapour compression refrigeration system using vapour injection technique
Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, 2020In modern days, the vapour compression refrigeration system is followed in almost all air-conditioning applications. Due to the high ambient temperature during extreme summer conditions, the commercial vapour compression refrigeration system made with cost competitiveness are not in a position to meet the required indoor conditions (27°C Dry Bulb ...
Chandramohan Rajamani +1 more
openaire +1 more source
Vapour Compression Refrigerators
1979This follows naturally on from chapter 11 since it deals with the reversed Rankine cycle and its various modifications. The most useful state diagram here is undoubtedly the pressure-enthalpy diagram since all processes except compression appear as straight lines on this field in elementary calculations.
openaire +1 more source
Electrons in Compressed Metal Vapours
Berichte der Bunsengesellschaft für physikalische Chemie, 1971AbstractA brief review of existing data on the specific conductivity and optical absorption of mercury and cesium at supercritical temperatures as a function of density is given. Since the paper contains a discussion of the metal‐nonmetal transition, its emphasis is on the intermediate range of conductivity between the metallic and nonmetallic state ...
openaire +1 more source
Simulation of vapour-compression heat pumps
SIMULATION, 1986A vapour compression heat pump simulation model has been developed to predict the overall performance of a system by employing a simple model for the components of the heat pump cycle - namely, the compressor, condenser and evaporator.Operating conditions, such as compressor speed, heat source and heat sink temperatures, cooling and heating fluids flow
openaire +1 more source
International Journal of Renewable Energy Technology, 2017
In this study, two types of refrigeration cycles, a vapour compression refrigeration (VCR) cycle and a vapour absorption refrigeration (VAR) cycle, have been modelled and analysed. Both the cycles have same operating cooling loads and both operate between the same temperature limits.
Sudip Ghosh +2 more
openaire +1 more source
In this study, two types of refrigeration cycles, a vapour compression refrigeration (VCR) cycle and a vapour absorption refrigeration (VAR) cycle, have been modelled and analysed. Both the cycles have same operating cooling loads and both operate between the same temperature limits.
Sudip Ghosh +2 more
openaire +1 more source
On the expansion and compression of saturated vapours
The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science(1868). On the expansion and compression of saturated vapours. The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science: Vol. 36, No. 242, pp. 238-240.
openaire +1 more source
Enhancement of the performance of the vapour compression plant
International Journal of Nuclear Desalination, 2010The objective of the present work is to study the performance of ejector vapour compression desalination plant with water spray on horizontal tube bundles. The effects of the operating conditions and the ejector geometry on the total distilled collected water are studied.
openaire +1 more source
Developments in Vapour Compression Heat Pumps
1983Until recently the vast majority of vapour compression heat pumps and refrigerators worked on the Rankine Cycle and were powered by an electric motor drive. However research and development work is proceeding to enable advances to be made with this system and to investigate and exploit the potential of alternative cycles and power sources.
openaire +1 more source
Magnetic pulse compression for a copper vapour laser
Journal of Physics D: Applied Physics, 1989A copper vapour laser (CVL) has been successfully operated with a magnetic pulse compression (MPC) driver. With the MPC circuit the laser output power is increased, and stresses on the thyratron are reduced leading to an increased tube life. A theoretical analysis of the MPC is presented and compared with experimental results.
M Nehmadi, Z Kramer, Y Ifrah, E Miron
openaire +1 more source
An optimization study of vapour compression desalination.
1970This item was digitized as part of a project to share McGill's intellectual legacy with the public. If you are the copyright holder or a relative of the copyright holder who is deceased, you may request withdrawal by emailing escholarship.library@mcgill.ca.
openaire +1 more source

