Results 241 to 250 of about 724,235 (283)
Some of the next articles are maybe not open access.
Principles of Vapour Compression Heat Pumps
1983The basic principles of operation of heat pumps and refrigeration devices are available in a great many references, several of which [1–4] were utilized in the preparation of this material. It is obvious that the basic principle of operation for a heat pump is the same as that of a refrigeration device except that for a heat pump attention is focused ...
openaire +1 more source
Analysis of vapour-compression refrigerating systems
2011The aim of this paper is to show the authors proposal for steady state numerical simulation of Vapour-Compression Refrigerating Systems (dry expansion, liquid overfeed systems, ...). The developed tool allows using different levels of simulation for some elements (compressors, pipes, etc.) as well as the possibility of use different kind of expansion ...
Sadurní Caballol, Alexandre +3 more
openaire +1 more source
Prime Movers for Vapour Compression Heat Pumps
1983The thermodynamic advantages of adopting heat engines rather than electric motors for driving heat pump are illustrated. The characteristics of the available heat engines (Diesel engines, gas engines, open cycle gas turbines, steam turbines, Rankine cycles, closed cycle gas turbines, Stirling engines) are discussed.
openaire +1 more source
The Determination of Mass Flow in the Vapour-Compression Refrigerator
Proceedings of the Institution of Mechanical Engineers, 1935The paper describes an experimental determination of the mass flow of refrigerant per minute and refrigerating effect per minute in a vapour-compression refrigerator, when the state of the refrigerant at the exit from the evaporator was varied over a wide range of superheat temperatures and dryness fractions. The usual methods of measuring the flow of
openaire +1 more source
Optimal control of vapour compression cycles
2004Une réduction de la consommation d'énergie d'un cycle à compression de vapeur peut être obtenue par un réglage optimal de chaque actionneur. Ce papier décrit la mise en oeuvre d'un contrôle optimal appliquant cette stratégie. Des essais ont été effectués à différentes échelles, allant de l'installation de laboratoire jusqu'à l'installation industrielle
openaire +1 more source
Experimental Facilities for Non-ideal Compressible Vapour Flows
ERCOFTAC Bulletin, 2020Spinelli, A. +7 more
openaire +2 more sources
EVAPORATION BY THE VAPOUR-COMPRESSION METHOD.