Results 61 to 70 of about 123,080 (295)

Design and Analysis of a Novel Variable Stiffness Joint for Robot

open access: yesMATEC Web of Conferences, 2018
As people pay more attention to the safety of human-robotic interaction, the flexibility of machine joints is becoming more and more important. To address the needs of future robotic applications, many kinds of variable stiffness mechanisms have been ...
Zhang Xiang   +2 more
doaj   +1 more source

Clinical Practice Guideline for Evaluation and Management of Peripheral Nervous System Manifestations in Sjögren's Disease

open access: yesArthritis Care &Research, EarlyView.
Objective Sjögren's disease is an autoimmune disorder that can impact multiple organ systems, including the peripheral nervous system (PNS). PNS manifestations, which can exist concurrently, include mononeuropathies, polyneuropathies, and autonomic nervous system neuropathies.
Anahita Deboo   +88 more
wiley   +1 more source

Design Characteristics of Continuum Robots Based on TSA Variable Stiffness Method

open access: yesActuators
To address the contradiction between high flexibility and low stiffness in continuum robots, as well as the problems of complex structure, slow response, and narrow stiffness adjustment range in existing variable stiffness methods, this paper proposes a ...
Gang Chen   +7 more
doaj   +1 more source

A Variable Stiffness Analysis Model for Large Complex Thin-Walled Guide Rail

open access: yesMATEC Web of Conferences, 2016
Large complex thin-walled guide rail has complicated structure and no uniform low rigidity. The traditional cutting simulations are time consuming due to huge computation especially in large workpiece.
Wang Xiaolong, Wang Aimin, Lv Yanpeng
doaj   +1 more source

Association Between Symptomatic Knee Osteoarthritis and Target Glycemic Control in Individuals With Type 2 Diabetes

open access: yesArthritis Care &Research, EarlyView.
Objective Knee osteoarthritis (OA) commonly affects individuals with type 2 diabetes (T2DM) and is associated with increased risk of diabetes‐related complications. To better understand potential mechanisms, we examined the association between symptomatic knee OA and glycemic control in individuals with T2DM.
Lauren K. King   +10 more
wiley   +1 more source

Variable-stiffness tensegrity spine

open access: yes
Vertebrates, including amphibians, reptiles, birds, and mammals, with their ability to change the stiffness of the spine to increase load-bearing capability or flexibility, have inspired roboticists to develop artificial variable-stiffness spines ...
Ajanic, Enrico   +3 more
core   +1 more source

Design of a Flexure-based Variable Stiffness Device for Cable-driven Joint Modules

open access: yes, 2015
Robots with variable stiffness can achieve intrinsically safe motions, which are essential for human-robot interactions. This paper aims to design a variable stiffness device (VSD) for cable-driven robots.
Yang, GL   +8 more
core   +1 more source

Preliminary Design and Control of an Ankle Rehabilitation Robot With Variable Stiffness Actuator

open access: yesIEEE Access
Intrinsic robotic compliance is crucial for enhancing the safety of physical human-robot interaction. This study proposes a variable stiffness ankle rehabilitation robot for rehabilitation training.
Laibin Luo   +4 more
doaj   +1 more source

Does Long‐Term Lower Extremity Strength Training in Adults With Knee Osteoarthritis and Varus Alignment Reduce Knee Joint Loading During Gait?

open access: yesArthritis Care &Research, EarlyView.
Objective We examined whether 18 months of strength training in individuals with knee varus alignment and medial tibiofemoral osteoarthritis (OA) reduced knee joint loads during walking compared to an attention control group. Methods This study was a secondary analysis of a randomized clinical trial that compared the effects of strength training to a ...
Stephen P. Messier   +12 more
wiley   +1 more source

Energy-Efficient Variable Stiffness Actuators [PDF]

open access: yes, 2011
Variable stiffness actuators are a particular class of actuators that is characterized by the property that the apparent output stiffness can be changed independent of the output position. To achieve this, variable stiffness actuators consist of a number
Raffaella Carloni   +7 more
core   +1 more source

Home - About - Disclaimer - Privacy