Experimental Study on the Interrelationships of VFTO, TEV, and EMF in Ultra-High Voltage Substations
2024 2nd China Power Supply Society Electromagnetic Compatibility Conference (CPEMC)The interrelationship between very fast transient over-voltage (VFTO), transient enclosure voltage (TEV), and electromagnetic fields (EMF) is crucial for understanding the formation mechanism of switching transients in Gas Insulated Substations (GIS ...
Jun Zhao +5 more
semanticscholar +1 more source
Exploring the Test Plan for the Impact of VFTO on Localized Protection Devices
Information Security Practice and Experience, 2021The State Grid Corporation of China is steadily promoting the research and trial operation of localized protection devices, and the very fast transient overvoltage (VFTO) nuisance caused by disconnecting switch operation in GIS may affect the normal ...
Ye Xia +5 more
semanticscholar +1 more source
Mitigation of VFTO from a Power Transformer bushing in a 275 kV Gas Insulated Substation
International Seminar on Intelligent Technology and Its ApplicationsVery Fast Transient Overvoltage (VFTO) is a potential cause of transformer bushing failures in Gas Insulated Substations (GIS). Protecting the power transformer from this dangerous overvoltage becomes imperative for the equipment safety.
Nasiru Yahaya Ahmed +5 more
semanticscholar +1 more source
Calculation of Influence of VFTO Signal on Insulation of Main Equipment in 500kV Power Station
2021 4th Asia Conference on Energy and Electrical Engineering (ACEEE), 2021The very fast transient over voltage (VFTO) caused by switching operation in GIS power station may threats equipment insulation especially transformers to research this problem, EMTP is adopted to calculate the overvoltage in 500 kV power station and a ...
Ren Hongtao, Chenyi Li
semanticscholar +1 more source
Study on VFTO Influence of Main Equipment’s Safety Performance in UHV Substation
2024 6th International Conference on Power and Energy Technology (ICPET)In UHV Gas Insulated Switchgear (GIS) substation, Very Fast Transient Overvoltage (VFTO) may occur during the operation of disconnector. VFTO stresses the GIS itself, turn-to-turn insulation of transformers, and all the secondary equipment connected to ...
Ruiming Fan, Lei Wan, Yang Li, Lei Wang
semanticscholar +1 more source
A Novel Capacitance Determination Method of Metal Oxide Arrester Blocks when Excited by VFTO
2021 IEEE 5th Conference on Energy Internet and Energy System Integration (EI2), 2021In recent years, the Ultra-High Voltage(UHV) and Extra-High Voltage (EHV) power system has been greatly developed. Subsequently, Gas Insulated Substation(GIS) has received more extensive attention and applications.
Jie Chen +5 more
semanticscholar +1 more source
Fractional Lumped Parameter Modeling of Transformer Windings under VFTO
Applied Mechanics and Materials, 2014Very fast transient overvoltage (VFTO) is very dangerous for the transformer which is directly connected to gas insulated substations (GIS). At the same time, due to the continuous increasing of operating frequency in the power system, under the high frequencies of the transmission line calculation and simulation process, it is necessary to consider ...
Gui Shu Liang, Guang Bo Zhang, Xin Liu
openaire +1 more source
Measurement And Analysis Of VFTO In a 750kV Substation
2010 Asia-Pacific Power and Energy Engineering Conference, 2010Disconnector operations in GIS may generate very fast transient overvoltage (VFTO), which is characterized by its high peak value, short rise time, and high frequencies. Mostly, researches on VFTO are focusing on the apparatus involving in the active circuit. However, VFTO may pass through open devices by electromagnetic coupling. To measure VFTO under
Jian Jiang +6 more
openaire +1 more source
Simulation of VFTO Suppression Methods for 1100kV GIS Substation
2019 IEEE 3rd Information Technology, Networking, Electronic and Automation Control Conference (ITNEC), 2019Disconnector switch operation in GIS will generate VFTO, which will harm the equipment. Because there are many limitations in field measurement, simulation can overcome the limitations of experimental research, which can replace test measurement to a certain extent. In this paper, three VFTO suppression methods are simulated in ATP-EMTP.
Wenxiu Gong +6 more
openaire +1 more source
Modeling for transformer windings under VFTO based on s-parameters
2008 International Conference on Machine Learning and Cybernetics, 2008To study the very fast transient over-voltage (VFTO) distribution in transformer windings in gas insulated substation (GIS), a systematic methodology based on s-parameters is presented for establishing high-frequency model of transformer windings in this paper.
null Ping Zhang +4 more
openaire +1 more source

