Results 31 to 40 of about 2,525,525 (348)

Heat‐pump performance: voltage dip/sag, under‐voltage and over‐voltage

open access: yesThe Journal of Engineering, 2014
Reverse cycle air‐source heat‐pumps are an increasingly significant load in New Zealand and in many other countries. This has raised concern over the impact wide‐spread use of heat‐pumps may have on the grid. The characteristics of the loads connected to the power system are changing because of heat‐pumps.
William J.B. Heffernan   +2 more
openaire   +2 more sources

Transient voltage stresses in MMC–HVDC links – impulse analysis and novel proposals for synthetic laboratory generation

open access: yesHigh Voltage, 2018
To evaluate and optimise insulation coordination concepts for state of the art high-voltage direct current (HVDC) transmission systems, appropriate test voltage shapes are required for laboratory imitation of occurring stresses.
Claudius Freye   +4 more
doaj   +1 more source

Voltage Ripple Reduction in Voltage Loop of Voltage Source Converter

open access: yesInternational Journal of Power Electronics and Drive Systems (IJPEDS), 2017
In order to achieve a good dynamical response of a full-bridge AC-DC voltage source converters (VSC). The bandwidth of PI controller must be relatively wide. This leads to the voltage ripple produced in the control signal, as known that its ripple frequency has twice of the line frequency and cause the 3rd harmonic of an input current. A Ripple Voltage
Jedsada Jaroenkiattrai, Viboon Chunkag
openaire   +1 more source

Research on 3‐D total electric field of crossing high voltage direct current transmission lines based on upstream finite element method

open access: yesHigh Voltage, 2021
The ongoing large‐scale construction of ultra high voltage direct current projects in China makes the crossing of two high voltage direct current (HVDC) lines inevitable.
Xiaoqian Ma, Li Xie, Kun He, Jiayu Lu
doaj   +1 more source

Voltage Graphs

open access: yesDiscrete Mathematics, 1974
AbstractA possible way to obtain a complicated graph imbedding in a surface is to derive it as a covering of a simpler imbedding by assigning “voltages” to the edges of the simpler imbedding. Although this new method is but the dual of the current graph construction,it has independent importance in practical applications, illustrated here by a ...
openaire   +2 more sources

A Quality Improvement Initiative to Standardize Pneumocystis jirovecii Pneumonia Prophylaxis in Pediatric Patients With Solid Tumors

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Pediatric patients with extracranial solid tumors (ST) receiving chemotherapy are at an increased risk for Pneumocystis jirovecii pneumonia (PJP). However, evidence guiding prophylaxis practices in this population is limited. A PJP‐related fatality at our institution highlighted inconsistent prescribing approaches and concerns about
Kriti Kumar   +8 more
wiley   +1 more source

Study of Transformer Core Vibration Considering Magnetostrictive Anisotropy

open access: yesActive and Passive Electronic Components
Due to the influence of the magnetostrictive effect of silicon steel sheet, the core inevitably generates vibration in the working process of the transformer, and at the same time, there are differences in the magnetostrictive properties of silicon steel
Jian Zhang   +3 more
doaj   +1 more source

Implications of Nonlinear Material Parameters on the Dielectric Loss under Harmonic Distorted Voltages

open access: yesEnergies, 2021
The increasing number of power electronic devices in electrical grids may lead to harmonic distorted voltages, which are considered to be possible causes of component failures. In this study, the dielectric losses of epoxy polymer and functionally filled
Thomas Linde   +5 more
doaj   +1 more source

Sickle Cell Disease Is an Inherent Risk for Asthma in a Sibling Comparison Study

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Introduction Sickle cell disease (SCD) and asthma share a complex relationship. Although estimates vary, asthma prevalence in children with SCD is believed to be comparable to or higher than the general population. Determining whether SCD confers an increased risk for asthma remains challenging due to overlapping symptoms and the ...
Suhei C. Zuleta De Bernardis   +9 more
wiley   +1 more source

Optimization of Low-Carbon Integrated Energy Systems With Efficient Hydrogen Use and Flexible CCPP-MR-HCHP Operations

open access: yesInternational Transactions on Electrical Energy Systems
With the increasing integration of renewable energy sources into the power system, challenges such as wind curtailment and operational flexibility are becoming more prominent.
Zheng Wang   +4 more
doaj   +1 more source