Results 11 to 20 of about 6,378 (207)

Power Stability Analysis and Evaluation Criteria of Dual-Infeed HVDC with LCC-HVDC and VSC-HVDC

open access: yesApplied Sciences, 2021
This paper analyzes the power stability of the hybrid dual-infeed high-voltage direct-current (HVDC) system containing a line commutated converter-based HVDC (LCC-HVDC) and a voltage source converter-based HVDC (VSC-HVDC).
Xinglong Wu, Zheng Xu, Zheren Zhang
doaj   +1 more source

Analysis of High Frequency Resonance and Suppression in Yu to E VSC-HVDC Project Connected to Power Grid

open access: yes发电技术, 2022
In view of the high frequency resonance generated by Yu side connected to the AC grid in the Yu to E voltage source converter based high voltage direct current transmission (VSC-HVDC) south channel project, the characteristics of VSC-HVDC converter ...
YANG Wankai, WANG Xingguo, WANG Shuyang
doaj   +1 more source

Experimental study on fault ride-through capability of VSC-based HVDC transmission system [PDF]

open access: yesArchives of Electrical Engineering, 2021
For voltage-source-converter based high-voltage-direct-current (VSC-HVDC) transmission systems, fault ride-through (FRT) capability is a very important grid requirement in order to enhance its operational availability under an alternating current (AC ...
Ngo Minh Khoa   +2 more
doaj   +1 more source

Multi-terminal HVDC grids with inertia mimicry capability [PDF]

open access: yes, 2016
The high-voltage multi-terminal dc (MTDC) systems are foreseen to experience an important development in the next years. Currently, they have appeared to be a prevailing technical and economical solution for harvesting offshore wind energy. In this study,
Gharehpetian, Gevorg B.   +4 more
core   +2 more sources

A Commutation Failure Suppression Control Method Based on the Controllable Operation Region of Hybrid Dual-Infeed HVDC System

open access: yesEnergies, 2018
With the increased use of high voltage direct current (HVDC) systems, line commutated converters (LCC-HVDC) and voltage source converters (VSC-HVDC) tend to feed into AC systems over short electrical distances.
Chao Xiao   +5 more
doaj   +1 more source

Study on fault ride-through control of islanded wind farm connected to VSC-HVDC grid based on the VSC converter AC-side bus forced short circuit

open access: yesThe Journal of Engineering, 2019
Wind farms integrated to an AC power system through a voltage source converter-based high-voltage direct current system (VSC-HVDC) are viewed as islanded wind farms. The wind farm side converter of VSC-HVDC maintains a constant frequency of the wind farm
Yan Li   +3 more
doaj   +1 more source

Overview of Research on Stability and Control of VSC-HVDC

open access: yes发电技术, 2019
Voltage source converter based high voltage direct current (VSC-HVDC) transmission systems has the advantages of good active and reactive power control capability and more suitable for multi-terminal transmission system.
Mingzhe WU, Wuhui CHEN
doaj   +1 more source

Impedance-compensated grid synchronisation for extending the stability range of weak grids with voltage source converters [PDF]

open access: yes, 2016
This paper demonstrates how the range of stable power transfer in weak grids with voltage source converters (VSCs) can be extended by modifying the grid synchronisation mechanism of a conventional synchronous reference frame phase locked loop (PLL).
D'Arco, Salvatore   +3 more
core   +2 more sources

Influence and comparison of P/Q-control based VSC-HVDC system on the grid power oscillation damping

open access: yesEnergy Reports, 2022
To analyze the dynamic process of VSC-HVDC system actively participating in suppressing the grid power oscillation, under the electromechanical time control scale, this paper establishes the linear mathematical model of the VSC-HVDC connected to the ...
Yuntao Xue   +4 more
doaj   +1 more source

Very long distance connection of gigawatt size offshore wind farms: extra high-voltage ac versus high-voltage dc cost comparison [PDF]

open access: yes, 2016
This study presents a cost comparison between commercially available high-voltage DC (HVDC) and extra high-voltage AC shore connection (±320 kV voltage source converter and 420 kV-50 Hz single-core and three-core cables), for a 1 GW offshore wind farm ...
LAURIA, Stefano   +3 more
core   +1 more source