Results 91 to 100 of about 9,686 (220)

Inertia emulation control of VSC-HVDC transmission system [PDF]

open access: yes, 2011
The increasing penetration of power electronics interfaced renewable generation (e.g. offshore wind) has been leading to a reduction in conventional synchronous-machine based generation.
Adam, Grain Philip   +3 more
core   +1 more source

Accurate Harmonic Voltage Measurement Based on Series Resistive‐Capacitive Divider for Gas‐Insulated Switchgear

open access: yesIET Science, Measurement &Technology, Volume 20, Issue 1, January/December 2026.
A series resistive‐capacitive divider for harmonic voltage measurement of gas‐insulated switchgear was studied. It can step down the voltage while amplifying the proportion of harmonics in the total sensed voltage, thereby increasing the significant figure for the measurement and enabling the accurate measurement of high‐order, low‐amplitude harmonics.
Huizhong Pang   +6 more
wiley   +1 more source

Nyquist Stability Analysis of an AC-Grid Connected VSC-HVDC System Using a Distributed Parameter DC Cable Model [PDF]

open access: yes, 2016
In this paper, a two-terminal VSC-HVDC system embedded in a weak grid ac environment is considered, emphasizing modeling, controller design, and small-signal stability analysis.
Breitholtz, Claes, Song, Yujiao
core   +1 more source

HVDC Cable System Testing

open access: yesHigh Voltage, Volume 10, Issue 6, Page 1349-1370, December 2025.
ABSTRACT This paper reviews the existing testing techniques for high voltage direct current (HVDC) cable systems, following as a backbone the structure of CIGRE Technical Brochure (TB) 852:2021 ‘Recommendations for testing DC extruded cable systems for power transmission at a rated voltage up to 800 kV’ because it has a fairly similar structure to ...
Giovanni Mazzanti
wiley   +1 more source

Optimal control design for VSC-HVDC systems [PDF]

open access: yes2013 International Conference on Electrical Engineering and Software Applications, 2013
This paper deals with modeling and optimal control design of VSC-HVDC transmission system in order to enhance system stability. The steady of the state mathematical model for GL (Generator-Load) VSC-HVDC system is developed and the decoupled relationship between the controlling variables is proposed.
Mohamed Ayari   +3 more
openaire   +1 more source

Harmonic Analysis of Transmission Scheme for Offshore Wind Farms Based on Diode Rectifier Unit

open access: yesEngineering Reports, Volume 7, Issue 10, October 2025.
This paper builds a general mathematical for the multiple rectifier circuit used in DRU, which is based on the 12‐pulse and 24‐pulse rectifier circuits, and analyzes the harmonics of DRU using different rectifier circuits before and after the installation of AC filters by an offshore wind farm integration project. ABSTRACT The diode rectifier unit (DRU)
Qing Chen   +4 more
wiley   +1 more source

Impact of short-duration voltage variations on VSC-HVDC performance. [PDF]

open access: yesSci Rep, 2023
Mostafa RA   +3 more
europepmc   +1 more source

Analysis of harmonics in subsea power transmission cables used in VSC-HVDC transmission systems operating under steady-state conditions [PDF]

open access: yes, 2007
Subsea power cables are a critical component of a voltage-source converter-high-voltage direct current (VSC-HVDC) transmission system in any offshore electrical power scheme.
Bucknall, R.W.G., Chien, C.H.
core  

MODELING AND SIMULATION OF VSC-HVDC WITH DYNAMIC PHASORS

open access: yesElectrica, 2008
A novel dynamic phasors method to model voltage sources converter based HVDC (VSC-HVDC) transmission system is proposed in this paper. This approach is based on the time-varying Fourier series coefficients of the system variables, and focused on the ...
Wei YAO, Jinyu WEN, Shijie CHENG
doaj   +2 more sources

Current-limiting characteristics of saturated iron-core fault current limiters in VSC-HVDC systems based on electromagnetic energy conversion mechanism

open access: yesJournal of Modern Power Systems and Clean Energy, 2018
A common method to examine the current-limiting performance of saturated iron-core fault current limiter (SI-FCL) in high-voltage direct-current transmission based on voltage source converter (VSC-HVDC) systems is to solve differential equations based on
Botong LI   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy